2003
DOI: 10.5433/1679-0359.2003v24n1p163
|View full text |Cite
|
Sign up to set email alerts
|

Monitoramento do índice biespectral em cães

Abstract: ResumoAtualmente, na tentativa de complementar a monitoração anestésica dos pacientes, utilizam-se a análise de variáveis clínicas ou técnicas eletrofisiológicas. Entretanto, é difícil utilizá-las para se obterem informações determinantes e uniformes dos planos anestésicos, para todos os agentes anestésicos. Conseqüentemente, foi desenvolvido, através de múltiplas investigações e avanços tecnológicos, o que se pode definir como monitor de profundidade anestésica, o monitor de índice biespectral (BIS). Desta fo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2008
2008
2022
2022

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 12 publications
(14 reference statements)
0
3
0
Order By: Relevance
“…The signal was acquired with electrodes (Sensor; Aspect Medical Systems, Inc) placed as described by Guerrero and Nunes (2003 Next, a teflon catheter was placed percutaneously in the jugular vein to collect blood (3ml), which was collected into tubes containing ethylene-diamine-tetra-acetic acid (EDTA). The blood was submitted to laboratory evaluation (Abovet da ABX, abc Pach LMGE Montpellier, São Paulo, Brazil) to assess red blood cell count (He), hematocrit (Ht), hemoblogin concentration (Hb), platelets and total leukocytes count (Le).…”
Section: Methodsmentioning
confidence: 99%
“…The signal was acquired with electrodes (Sensor; Aspect Medical Systems, Inc) placed as described by Guerrero and Nunes (2003 Next, a teflon catheter was placed percutaneously in the jugular vein to collect blood (3ml), which was collected into tubes containing ethylene-diamine-tetra-acetic acid (EDTA). The blood was submitted to laboratory evaluation (Abovet da ABX, abc Pach LMGE Montpellier, São Paulo, Brazil) to assess red blood cell count (He), hematocrit (Ht), hemoblogin concentration (Hb), platelets and total leukocytes count (Le).…”
Section: Methodsmentioning
confidence: 99%
“…The BIS was computed by an Aspect A‐2000 monitor (Aspect Medical Systems, Inc, Natick, MA, USA). The signal was acquired with electrodes (BIS Sensor; Aspect Medical Systems, Inc) placed as described by Guerrero & Nunes (2003). The following data were recorded: BIS value, which is displayed as outlined numbers when the signal quality index (SQI) is <50, and in solid block form when the signal quality is adequate and >50; SQI, ranging from 0 to 100 .…”
Section: Methodsmentioning
confidence: 99%
“…The value of BIS was assessed using BIS Vista 3.01 (Aspect Medical Systems Inc., Mansfield, MA02048, USA). First, electrodes (Covidien, Mansfield, MA 02048, USA) were positioned as described by Guerrero and Nunes [7]. Then, to ensure strong brainwave signals, signal quality index and electromyogram values were set at >30.…”
Section: Bis Measurementmentioning
confidence: 99%