2008
DOI: 10.1016/j.bios.2008.06.017
|View full text |Cite
|
Sign up to set email alerts
|

Mixed self-assembly of polydiacetylenes for highly specific and sensitive strip biosensors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
18
0

Year Published

2010
2010
2019
2019

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 16 publications
(19 citation statements)
references
References 15 publications
1
18
0
Order By: Relevance
“…However, when an overdose of anti-MC-LR is absorbed onto the sensor surfaces, because there is insufficient room, the MC-LR may be prevented from approaching or the anti-MC-LR may not rotate to cause backbone change of PDA as a result of the steric effect. These responses are in accordance with research on the avidin-biotin interaction based on PDA [19]. This finding is highly significant for immunosensor fabrication dependent on three-dimensional conformations because, on one hand, it greatly reduces the unnecessary cost of expensive antibody; and on the other hand, it is effective in enhancing the sensitivity of biosensors.…”
Section: Selection Of the Optimum Condition For Recognitionsupporting
confidence: 86%
See 3 more Smart Citations
“…However, when an overdose of anti-MC-LR is absorbed onto the sensor surfaces, because there is insufficient room, the MC-LR may be prevented from approaching or the anti-MC-LR may not rotate to cause backbone change of PDA as a result of the steric effect. These responses are in accordance with research on the avidin-biotin interaction based on PDA [19]. This finding is highly significant for immunosensor fabrication dependent on three-dimensional conformations because, on one hand, it greatly reduces the unnecessary cost of expensive antibody; and on the other hand, it is effective in enhancing the sensitivity of biosensors.…”
Section: Selection Of the Optimum Condition For Recognitionsupporting
confidence: 86%
“…The immunoassay based on PDA lipids has attracted much attention with its blue-to-red color and accompanying fluorescence changes [19,35]. In the present work, the use of EDC/NHS enabled mAbs of MC-LR (anti-MC-LR)-MC8C50 to covalently link to the carboxyl groups of PDA vesicles after photopolymerization, without substantially affecting the activity of the protein [21,34].…”
Section: Selection Of the Optimum Condition For Recognitionmentioning
confidence: 98%
See 2 more Smart Citations
“…This interest is due to the fact that PDA-based materials have different colorimetric characteristics, depending on some environmental conditions. Changes in their color, usually from blue to red, in response to some stimuli, such as temperature [1][2][3], pH [4,5], mechanical disturbances [6], solvents [7], and recognition of substances [8], have promoted the effective use of PDA vesicles in the development of colorimetric analysis [9][10][11], chips [12,13] and biosensors [14,15]. The correct mechanism to explain color transition from blue to red, due to different stimuli has not been discovered.…”
Section: Introductionmentioning
confidence: 99%