2022
DOI: 10.1016/j.talanta.2022.123737
|View full text |Cite
|
Sign up to set email alerts
|

MIP-based electrochemical sensor for direct detection of hepatitis C virus via E2 envelope protein

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 18 publications
(6 citation statements)
references
References 60 publications
0
6
0
Order By: Relevance
“…Antipchik et al [ 123 ] published the first report on the development of an MIP-based electrochemical sensor for detecting the hepatitis C virus via its surface protein E2. Green fluorescent protein was used in conjunction with E2 (total MW of 54 kDa) to prevent protein agglomeration and stabilize its structure.…”
Section: Mip Application For the Detection Of Biomarkers Of Infectiou...mentioning
confidence: 99%
See 1 more Smart Citation
“…Antipchik et al [ 123 ] published the first report on the development of an MIP-based electrochemical sensor for detecting the hepatitis C virus via its surface protein E2. Green fluorescent protein was used in conjunction with E2 (total MW of 54 kDa) to prevent protein agglomeration and stabilize its structure.…”
Section: Mip Application For the Detection Of Biomarkers Of Infectiou...mentioning
confidence: 99%
“… Schematic representation of HCV diagnostics principle by HCV sensor. Reprinted with permission from [ 123 ]. …”
Section: Figurementioning
confidence: 99%
“…Several studies reported in the literature have successfully demonstrated the use of MIPs for the quantification of large molecules such as proteins and drugs [ 31 , 32 , 33 ] since these analytes could enter into the cavities of the imprinted polymer. However, it is worth noting that sensors based on only MIP generally do not have as suitable conductivity [ 34 ].…”
Section: Introductionmentioning
confidence: 99%
“…Accordingly, molecular imprinting has become one of the most important techniques for fabricating synthetic ligands on sensor surfaces [17,19]. MIPs have been successfully coupled to surface plasmon resonance (SPR) sensors [23], quartz crystal microbalance sensors [24], luminescence probes [25] and electrochemical sensors [26,27]. Molecular-imprinted fluorescent sensors (MIFS) have been used for detection of several organic molecules and metal ions including proteins [28], caffeine [29] and cocaine [30] in addition to silver [31] and aluminum ions [32].…”
Section: Introductionmentioning
confidence: 99%