Miniaturised hybrid immunoassay for high sensitivity analysis of aflatoxin M1 in milk

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
24
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
6
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 42 publications
(24 citation statements)
references
References 25 publications
0
24
0
Order By: Relevance
“…Regarding the method used for the identification of AFM 1 in bovine milk, it showed a good sensitivity and precision for the quantification of aflatoxin within the Brazilian parameters, although there are also very sensitive methods for detection of aflatoxin M1 (Vdovenko et al, 2014;Kanungo et al, 2011).…”
Section: Resultsmentioning
confidence: 99%
“…Regarding the method used for the identification of AFM 1 in bovine milk, it showed a good sensitivity and precision for the quantification of aflatoxin within the Brazilian parameters, although there are also very sensitive methods for detection of aflatoxin M1 (Vdovenko et al, 2014;Kanungo et al, 2011).…”
Section: Resultsmentioning
confidence: 99%
“…The author reported a LOD of 30 pg/mL with the high throughput ELISA procedure. In the last decades, nanomaterial-based signal amplification strategies for conventional ELISA and electrochemical detection have been applied for AFM1 detection [53,54]. For AFB1 detection, an impedimetric immunosensor based on colloidal gold and silver electrodeposition for AFM1 detection was developed by Vig et al [55].…”
Section: Electrochemical Immunosensors For Afs Detectionsmentioning
confidence: 99%
“…The hybrid-assay, by coupling the 1 antibodies (Ab) immobilized MNPs column with microwell plate assay enabled simultaneous measurement of low (0.5 pg/mL) and high AFM1 contamination (200 pg/mL). The MNPs-ELISA advantages were that it had a small column size, high capture efficiency and lower cost over other reported materials [46].…”
Section: Update On Aflatoxin M1 Extraction Detection and Quantificatmentioning
confidence: 99%
“…This method showed a 2% of false negative results. Kanungo et al [46] also developed an ultra-sensitive sandwich for the detection of AFM1 in milk. The assay involved the immobilization of rat monoclonal antibody of AFM1 in 384 microtiter plate to capture AFM1 antigen.…”
Section: Update On Aflatoxin M1 Extraction Detection and Quantificatmentioning
confidence: 99%
See 1 more Smart Citation