2018
DOI: 10.1002/mrm.27053
|View full text |Cite
|
Sign up to set email alerts
|

Millimeter spatial resolution in vivo sodium MRI of the human eye at 7 T using a dedicated radiofrequency transceiver array

Abstract: Three most important eye compartments in the context of sodium physiology were clearly delineated in all of the images: the vitreous humor, the aqueous humor, and the lens. Our results provide encouragement for further clinical studies. The implications for research into eye diseases including ocular melanoma, cataract, and glaucoma are discussed. Magn Reson Med 80:672-684, 2018. © 2018 International Society for Magnetic Resonance in Medicine.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 7 publications
(8 citation statements)
references
References 48 publications
(83 reference statements)
0
8
0
Order By: Relevance
“… and Fig. , respectively. State‐of‐the‐art coils for 35 Cl, 17 O, and 39 K imaging are transmit‐and‐receive birdcage coils.…”
Section: Current State and Technical Challengesmentioning
confidence: 94%
See 1 more Smart Citation
“… and Fig. , respectively. State‐of‐the‐art coils for 35 Cl, 17 O, and 39 K imaging are transmit‐and‐receive birdcage coils.…”
Section: Current State and Technical Challengesmentioning
confidence: 94%
“…Different Na setups have been reviewed for applications in the head, the heart, and in the body . The latest developments in RF coils for X‐nuclei imaging focus on setups comprising multiple transmit‐and‐receive coils, especially for 23 Na MRI . Exemplary images in the abdomen and the eyes are shown in Fig.…”
Section: Current State and Technical Challengesmentioning
confidence: 99%
“…Given the intrinsic sensitivity gains achievable at higher magnetic field strengths, 23 Na MRI at B 0 = 7.0 Tesla (T) is conceptually appealing. Recognizing this opportunity, a number of RF coil setups have been implemented at 7.0 T for 23 Na MRI of the brain, eye, lung and abdomen, and musculoskeletal system . The literature reveals a single original report for 23 Na MRI of the kidney at 7.0 T .…”
Section: Introductionmentioning
confidence: 99%
“…Red arrows in Fig. 1 represent discrete ports (16) used for the electromagnetic field simulations: impedance value = 50 Ω (for S-parameter), voltage amplitude = 1 V, and current value = 1 A. Two stimulation ports were set on one end-ring and these ports were used to send the electric signals to the coil with the phase shift = 90° in the EMC simulations.…”
Section: Radiofrequency Coil Designmentioning
confidence: 99%
“…In the CST Studio, each element of the coil circuit was tuned to the resonance frequency of 300 MHz and matched to the impedance of 50 Ω. Failure to properly tune and match the coil may result in noisy images with poor contrast in the experiments [16,17]. In our study, we used a manual tuner for changing values of capacitors.…”
Section: Electrical Circuit Modelmentioning
confidence: 99%