2019
DOI: 10.1002/mrm.27880
|View full text |Cite
|
Sign up to set email alerts
|

Cardiorenal sodium MRI at 7.0 Tesla using a 4/4 channel 1H/23Na radiofrequency antenna array

Abstract: Purpose Cardiorenal syndrome describes disorders of the heart and the kidneys in which a dysfunction of 1 organ induces a dysfunction in the other. This work describes the design, evaluation, and application of a 4/4‐channel hydrogen‐1/sodium (1H/23Na) RF array tailored for cardiorenal MRI at 7.0 Tesla (T) for a better physiometabolic understanding of cardiorenal syndrome. Methods The dual‐frequency RF array is composed of a planar posterior section and a modestly curved anterior section, each section consisti… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
17
0
3

Year Published

2021
2021
2023
2023

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 18 publications
(21 citation statements)
references
References 68 publications
(77 reference statements)
1
17
0
3
Order By: Relevance
“…50 Lastly, we note that wireless systems that can transfer data at low and high data rates both have potential in MRI as each is highly dependent upon the RF coil array application. For example, an extremely high data rate system is required for high-density neuroimaging coil arrays, 1,2 but a lower data rate system with cheaper electronics would be suitable for a four-channel cardiorenal coil array 51 or the aforementioned eight-channel HIC glove array.…”
Section: Wireless Rf Coil Arrays For Wireless Mri Data Transfermentioning
confidence: 99%
“…50 Lastly, we note that wireless systems that can transfer data at low and high data rates both have potential in MRI as each is highly dependent upon the RF coil array application. For example, an extremely high data rate system is required for high-density neuroimaging coil arrays, 1,2 but a lower data rate system with cheaper electronics would be suitable for a four-channel cardiorenal coil array 51 or the aforementioned eight-channel HIC glove array.…”
Section: Wireless Rf Coil Arrays For Wireless Mri Data Transfermentioning
confidence: 99%
“…In particular, an EM-field simulation is essential to more accurately predict the safety of RF coils as EM-fields play an important role in the generation of B 1 -fields and SAR distributions . Owing to these problems, various studies have been conducted with an aim to increase the uniformity of the B 1 -field [26][27][28][29][30][31][32][33][34][35][36][37] and to improve the sensitivity of the B 1 -field [38][39][40][41][42][43][44][45] along with RF safety [46][47][48][49][50][51][52][53][54][55][56][57].…”
Section: Introductionmentioning
confidence: 99%
“…Four T/R switches are used to receive the signals from four 23Na RF coils of oval shape working at 7‐Tesla torso MRI 7 . A 4/4 1H/23Na RF coil is designed for cardiorenal 7‐Tesla MRI 8 . In that work, four T/R switches are used with 1H and four T/R switches are tuned for 23Na, all switches were from Stark Contrast, Erlangen, Germany.…”
Section: Introductionmentioning
confidence: 99%