A Preliminary Study for Reference RF Coil at 11.7 T MRI: Based on Electromagnetic Field Simulation of Hybrid-BC RF Coil According to Diameter and Length at 3.0, 7.0 and 11.7 T

Abstract: Magnetic resonance imaging (MRI) systems must undergo quantitative evaluation through daily and periodic performance assessments. In general, the reference or standard radiofrequency (RF) coils for these performance assessments of 1.5 to 7.0 T MRI systems have been low-pass-type birdcage (LP-BC) RF coils. However, LP-BC RF coils are inappropriate for use as reference RF coils because of their relatively lower magnetic field (B1-field) sensitivity than other types of BC RF coils, especially in ultrahigh-field (… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(9 citation statements)
references
References 88 publications
0
9
0
Order By: Relevance
“…By distributing series capacitors on both end-ring and leg conductor segments this issue is avoided. In addition, the hybrid topology has a more balanced field/voltage distribution across its structure leading to improved insensitivity to loading and avoiding large conservative electric fields that would increase the localized SAR [30], [31]. A 1.4 m long conductive shield with 55 cm diameter encompasses both designs in simulation to account for the outer conductor (RF shield) of the bore.…”
Section: Practical Metamaterials Liner a Metamaterials Liner And Bird...mentioning
confidence: 99%
See 1 more Smart Citation
“…By distributing series capacitors on both end-ring and leg conductor segments this issue is avoided. In addition, the hybrid topology has a more balanced field/voltage distribution across its structure leading to improved insensitivity to loading and avoiding large conservative electric fields that would increase the localized SAR [30], [31]. A 1.4 m long conductive shield with 55 cm diameter encompasses both designs in simulation to account for the outer conductor (RF shield) of the bore.…”
Section: Practical Metamaterials Liner a Metamaterials Liner And Bird...mentioning
confidence: 99%
“…By placing distributed series capacitors on both end-ring and leg conductor segments this mode can be excited despite the large dimensions of the coil. In addition, the hybrid topology has a more balanced field/voltage distribution across its structure leading to greater insensitivity to loading and minimizing large conservative electric fields that would increase the localized SAR [30], [31].…”
Section: Alternative Bc Sar Reduction Strategiesmentioning
confidence: 99%
“…Plasma ignition in a plasma source with the birdcage resonator at a frequency relevant to today's state-of-the-art MRI devices [13], [14] was not studied up to this moment. Our team have already brought preliminary work on this topic [15], [16]; however, only the electrical properties of the resonators have been studied yet.…”
Section: Introductionmentioning
confidence: 99%
“…A conventional MRI is a closed system with a bore diameter of 60 cm and a magnetic field of 1.5 T. Recently, open MRI FIGURE 1 (a) Electrical circuit of MRI system and (b) trimmer location in matching block [1] γ is equal to 42.58 MHz/T [3]. The 3 T magnetic field strength implies higher operating frequencies f Larmor (128 MHz versus 64 MHz for traditional closed MRI systems), which leads to better tissue penetration and thus improving the image quality [4].…”
Section: Introductionmentioning
confidence: 99%
“…At the end of the RF excitation, each atom sends back a RF wave with a frequency depending on its position. The information is then processed to build a 3D image [1].…”
Section: Introductionmentioning
confidence: 99%