2011
DOI: 10.1039/c0lc00524j
|View full text |Cite
|
Sign up to set email alerts
|

Microfluidic paper-based chemiluminescence biosensor for simultaneous determination of glucose and uric acid

Abstract: In this study, a novel microfluidic paper-based chemiluminescence analytical device (μPCAD) with a simultaneous, rapid, sensitive and quantitative response for glucose and uric acid was designed. This novel lab-on-paper biosensor is based on oxidase enzyme reactions (glucose oxidase and urate oxidase, respectively) and the chemiluminescence reaction between a rhodanine derivative and generated hydrogen peroxide in an acid medium. The possible chemiluminescence assay principle of this μPCAD is explained. We fou… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
165
0
2

Year Published

2012
2012
2023
2023

Publication Types

Select...
7
3

Relationship

0
10

Authors

Journals

citations
Cited by 300 publications
(174 citation statements)
references
References 54 publications
3
165
0
2
Order By: Relevance
“…4 Paper based chemiluminescence biosensors for the simultaneous detection and quantification of glucose and uric acid in artificial urine have already been demonstrated. 5 Other useful features of paper based sensing devices or fuel cells are low cost, ease of use and disposal, and low consumption of reagents. Therefore, paper based fuel cells are viable alternatives to battery operated MNSs for the former are not only cheap, but are also made up of less toxic components.…”
Section: Introductionmentioning
confidence: 99%
“…4 Paper based chemiluminescence biosensors for the simultaneous detection and quantification of glucose and uric acid in artificial urine have already been demonstrated. 5 Other useful features of paper based sensing devices or fuel cells are low cost, ease of use and disposal, and low consumption of reagents. Therefore, paper based fuel cells are viable alternatives to battery operated MNSs for the former are not only cheap, but are also made up of less toxic components.…”
Section: Introductionmentioning
confidence: 99%
“…自 2007 年 whitesides 组 [1] 首次提出这个概念以来, 纸芯 片因其原料廉价易得、易加工、生物兼容性好、无需外 力驱动液流等特点受到了科研工作者极大的关注, 在临 床医学诊断, 食品安全检测以及环境质量监控等多个领 域展现了巨大的应用前景. 近几年来, 文献相继报道了紫外光处理 [1 ~ 4] 、蜡 印 [5,6] 、溶剂刻蚀 [7,8] 、等离子体处理 [9] [16,17] 、化学发光法 [18,19] 和电化学法 [20,21] 等. 本文参照 文献 [17], 利用 Trinder 反应所得显色产物的颜色深浅对 血液中葡萄糖含量进行测定.…”
Section: 引言unclassified
“…However, they have not been widely used in paper-based microfluidics; only a few studies investigated using these two detection methods for detecting analytes in paper-based microfluidic devices or paper-based microarray plates. 16,19,41 Figure 5(c) shows an approach of conducting ECL detection on paper-based microfluidic devices.…”
Section: The Application Of Paper-based Microfluidic Devicesmentioning
confidence: 99%