Methods to determine the joint strength of C/C to copper joints

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2007
2007
2020
2020

Publication Types

Select...
5
2
2

Relationship

1
8

Authors

Journals

citations
Cited by 12 publications
(6 citation statements)
references
References 10 publications
0
5
0
Order By: Relevance
“…For those parameters damage is governed by the low value of G c . That emphasizes the need for bond characterisation, which was investigated in [13] and still is a matter of ongoing research [17]. Using previous tensile and shear bond test results [6][13] to identify the parameters, the following set of parameters was identified at room temperature: σ c = 43 MPa, G I c =1900 J.m -2 , G II c =3000 J.m -2 .…”
Section: Crack Initiation and Propagationmentioning
confidence: 99%
“…For those parameters damage is governed by the low value of G c . That emphasizes the need for bond characterisation, which was investigated in [13] and still is a matter of ongoing research [17]. Using previous tensile and shear bond test results [6][13] to identify the parameters, the following set of parameters was identified at room temperature: σ c = 43 MPa, G I c =1900 J.m -2 , G II c =3000 J.m -2 .…”
Section: Crack Initiation and Propagationmentioning
confidence: 99%
“…L-shaped tiles have a 45° inclination of the carbon fibre planes with respect to the bonding interface. HHF test results performed on GLADIS validated this concept [7]. The casting of the 3 mm thick AMC ® copper interlayer of the reference design will be used for the serial production of the L-shaped tiles.…”
Section: Bond Of the Tiles To The Cooling Structurementioning
confidence: 75%
“…An improvement was achieved by performing this process in presence of silicon in addition. This improvement was demonstrated by a push-test in the shear plane introduced by Plansee SE [7,8]. The samples showed a measured value of ~ 30 MPa and ~ 60 MPa without and with silicon, respectively.…”
Section: Bond Of the Tiles To The Cooling Structurementioning
confidence: 99%
“…Indeed, in the CFC the tensile state in the X direction, measured in the as-brazed specimen, is turned into compressive, remaining well below the compressive strength of NB31 along this direction. Schedler et al [12] showed that the CFC-Cu joint strength is weakened after treatments such as quenching and thermal fatigue, due to the formation of microcracks which reduce the integral capability of the joint to transfer mechanical loads. The observed residual stress relaxation could be ascribed to this phenomenon as well.…”
Section: Resultsmentioning
confidence: 99%