2007
DOI: 10.1088/0031-8949/2007/t128/037
|View full text |Cite
|
Sign up to set email alerts
|

Fabrication and testing of W7-X pre-series target elements

Abstract: The assembly of the highly-loaded target plates of the WENDELSTEIN 7-X (W7-X) divertor requires the fabrication of 890 target elements. The plasma facing material is made of CFC NB31 flat tiles bonded to CuCrZr copper alloy water-cooled heat sink. The elements are designed to remove a stationary heat flux and power up to 10 MW/m 2 and 100 kW, respectively. Before launching the serial fabrication, pre-series activities aimed at qualifying the design, the manufacturing route and the nondestructive examinations. … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2009
2009
2018
2018

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 11 publications
0
4
0
Order By: Relevance
“…CFC tiles which have typical dimensions of 25 mm length, 55 mm width and 8 mm thickness were bonded onto the cooling structure with the highest thermal conductivity (ex-pitch fibres) normal to the cooling structure, ex-PAN fibres across theelement and needling direction along the element [11]. Three new variants of CFC/Cu bonding have been investigated:…”
Section: Variants Of Manufactured Cfc/cu-bondingmentioning
confidence: 99%
“…CFC tiles which have typical dimensions of 25 mm length, 55 mm width and 8 mm thickness were bonded onto the cooling structure with the highest thermal conductivity (ex-pitch fibres) normal to the cooling structure, ex-PAN fibres across theelement and needling direction along the element [11]. Three new variants of CFC/Cu bonding have been investigated:…”
Section: Variants Of Manufactured Cfc/cu-bondingmentioning
confidence: 99%
“…The monoblock geometry always induces a thermal gradient between the outer edges and the centre of the CFC blocks. A misalignment in the orientation of the carbon fiber mesh during production of the CFC results in further asymmetries of the surface temperature [12], [13]. Therefore, the resulting surface temperature distribution is not uniform as expected from the Gaussian distributed heat load.…”
Section: High Heat Flux Test Campaignmentioning
confidence: 99%
“…The acceptance criteria are the same as for the W7-X divertor target elements [8]: a leak rate lower than 5 × 10 −7 Pa l/s at room temperature and 3.2 MPa internal He pressure, and a leak rate lower than 5 × 10 −6 Pa l/s at 160 • C and 2.5 MPa internal He pressure.…”
Section: Full-scale Pfc Prototypementioning
confidence: 99%