2020
DOI: 10.13057/biodiv/d210955
|View full text |Cite
|
Sign up to set email alerts
|

Metabolic profiling and pathway analysis in red arillus of Salacca sumatrana demonstrate significant pyruvate, sulfur, and fatty acid metabolisms

Abstract: Abstract. Fendiyanto MH, Satrio RD, Darmadi D. 2020. Metabolic profiling and pathway analysis in red arillus of Salacca sumatrana demonstrate significant pyruvate, sulfur, and fatty acid metabolisms. Biodiversitas 21: 4361-4368. Salak or snake fruit (Salacca Reinw.; Arecaceae) is a tropical fruit that has high biodiversity in a tropical country such as Indonesia. Several types of salak can be found in Indonesia, one of which is Salacca sumatrana (Becc.) Mogea. Research on profiling metabolites in S. sumatrana … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
15
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
1

Relationship

2
3

Authors

Journals

citations
Cited by 9 publications
(16 citation statements)
references
References 36 publications
(38 reference statements)
1
15
0
Order By: Relevance
“…GC-MS analysis was carried out by following Fendiyanto et al (2020) and Pratami (2020) with minor modifications. A total of 5 grams of arillus was extracted using methanol (50 ml solvent) at 25 °C for 72 h, shaken with a 50 rpm shaker (proportion: 1 g sample:10 ml solvent), modified by Park et al (2019) and Fendiyanto et al (2020). The extract was then evaporated for 60 min using an evaporator (Caliper-Life-Science, USA) at 45 °C.…”
Section: Analysis Of Gas Chromatography-mass Spectrometry (Gc-ms)mentioning
confidence: 99%
See 4 more Smart Citations
“…GC-MS analysis was carried out by following Fendiyanto et al (2020) and Pratami (2020) with minor modifications. A total of 5 grams of arillus was extracted using methanol (50 ml solvent) at 25 °C for 72 h, shaken with a 50 rpm shaker (proportion: 1 g sample:10 ml solvent), modified by Park et al (2019) and Fendiyanto et al (2020). The extract was then evaporated for 60 min using an evaporator (Caliper-Life-Science, USA) at 45 °C.…”
Section: Analysis Of Gas Chromatography-mass Spectrometry (Gc-ms)mentioning
confidence: 99%
“…The extract (5 μl) in split is then injected into the GC-MS Instrument with the following equipment specifications: main instrument (7890, Agilent Tech-Palo Alto-USA), auto-sampler (7693, Agilent Tech-Palo Alto-USA), Mass Selective Detector, and a Chemstation Dataset System (5975 inert MSD Detector, Agilent Tech-Palo Alto-USA). Instruments covering injection temperature and temperature of various instruments, mass spectrum detection, and metabolite identification were carried out following Fendiyanto et al 2020. Instruments settings in this study were 230°C of ion source temperature, 250°C of injection temperature, 140°C of quadrupole temperature, and 280°C of interface temperature.…”
Section: Analysis Of Gas Chromatography-mass Spectrometry (Gc-ms)mentioning
confidence: 99%
See 3 more Smart Citations