The platform will undergo maintenance on Sep 14 at about 7:45 AM EST and will be unavailable for approximately 2 hours.
1970
DOI: 10.1016/0550-3213(70)90389-5
|View full text |Cite
|
Sign up to set email alerts
|

Measurements of the longitudinal and lateral development of electromagnetic cascades in lead, copper and aluminum at 6 GeV

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
15
0

Year Published

1973
1973
2011
2011

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 37 publications
(15 citation statements)
references
References 10 publications
0
15
0
Order By: Relevance
“…Common disadvantages are limited range of linearity, perturbation of the shower by the detector itself and difficulty achieving adequate statistical weight. Two experiments performed in 1969-1970 [9,10], specifically to characterize electromagnetic showers in several materials, are particularly suitable for benchmarking because they measured deposited energy to large radii and depths. They used small detectors with good spatial resolution that perturbed the shower to a minimal extent, and controlled the beam in order to keep the detectors in a verifiably linear range.…”
Section: Experimental Measurements Of Electromagnetic Showersmentioning
confidence: 99%
See 2 more Smart Citations
“…Common disadvantages are limited range of linearity, perturbation of the shower by the detector itself and difficulty achieving adequate statistical weight. Two experiments performed in 1969-1970 [9,10], specifically to characterize electromagnetic showers in several materials, are particularly suitable for benchmarking because they measured deposited energy to large radii and depths. They used small detectors with good spatial resolution that perturbed the shower to a minimal extent, and controlled the beam in order to keep the detectors in a verifiably linear range.…”
Section: Experimental Measurements Of Electromagnetic Showersmentioning
confidence: 99%
“…An investigation of shower energy deposition by 6 GeV electrons [10] was carried out using silver phosphate glass dosimeters, 1 mm diameter by 6 mm long. It was shown that relative errors in dose measurements between samples were less than 5%.…”
Section: Description Of the Experimentsmentioning
confidence: 99%
See 1 more Smart Citation
“…These studies confirmed that there was good theoretical understanding of these processes (67). Photon spectra at .accelerators up to now have not been measured, but a [3--y spectrometer and a Nai(Tl) anticoincidence -y-ray spectrometer have been used to measure dose rate for space missions (68,69).…”
Section: B Electron Acceleratorsmentioning
confidence: 61%
“…On average, a cylinder with radius R M contains 90% of the total deposited energy; a cylinder with radius 3.5R M contains 99% [177]. In the transverse direction, the edge of a shower block is only about 1.6R M from its center; for this reason, our analysis groups neighboring blocks into clusters, which catch more of the cascade.…”
Section: Preshower and Showermentioning
confidence: 99%