2017
DOI: 10.1016/j.flowmeasinst.2016.08.003
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of velocity of gas/solid swirl flow using Electrical Capacitance Tomography and cross correlation technique

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
22
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 45 publications
(22 citation statements)
references
References 17 publications
0
22
0
Order By: Relevance
“…The cross-correlation is commonly applied to detect the delay of a signal with a known or assumed waveform [ 4 , 5 , 6 , 26 , 27 , 28 , 29 , 30 ]. A common error of the cross-correlation is the detection of a secondary maximum instead of the real one [ 26 ].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The cross-correlation is commonly applied to detect the delay of a signal with a known or assumed waveform [ 4 , 5 , 6 , 26 , 27 , 28 , 29 , 30 ]. A common error of the cross-correlation is the detection of a secondary maximum instead of the real one [ 26 ].…”
Section: Methodsmentioning
confidence: 99%
“…However, HSC requires an optical access to a measurement volume, which is not always possible such as in the case of optically opaque pipes or fluids. Optical access is not required by electrical capacitance or conductance sensors [ 4 , 5 , 6 ] nor by the gamma-ray tomography [ 7 , 8 , 9 ]. However, their resolution does not allow for resolving each bubble in a bubbly flow.…”
Section: Introductionmentioning
confidence: 99%
“…In order to check the proposed approach, it was applied on real data sets derived from the ECT system. The ECT system had specifically designed sensors, which comprises 16 measuring electrodes, organised in two layers of eight electrodes each made of copper with a thickness of 0.2 mm, width of 50 mm for each one, and height of 30 mm. The external screen is made of a copper sheet with a thickness of 0.5 mm connected to the grounding measurement system; insulation of the external screen is made of polyurethane foam dielectric (permittivity of 1.6), whilst the two internal screen boundaries made of copper tape have a thickness of 0.2 mm and height of 25 mm each.…”
Section: Methods Validationmentioning
confidence: 99%
“…Recently, the method for angular velocity measurements in a case of a swirl flow was published . It is based on statistical spatio‐temporal analysis of tomographic images, captured by a twin‐plane tomography system.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation