1990
DOI: 10.1080/15298669091369385
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of Organic Vapors at Sub-TLV® Concentrations Using Fast Gas Chromatography

Abstract: Gas chromatography usually is considered too slow a method to be useful for real-time or near real-time monitoring. If the chromatographic system is optimized for speed, however, it is possible to reduce retention times significantly. Recently, a fast gas chromatograph (GC) was described that allows many simple separations to be completed in 10 sec or less. The system features a gas-cooled, electrically heated, capillary cold trap that focuses the sample as an extremely narrow band at the front of the column. … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
5
0

Year Published

1991
1991
2003
2003

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 0 publications
0
5
0
Order By: Relevance
“…BTEX (Benzene, Toluene, Ethylbenzene and Xylene) compounds (1-4) are important components of gasoline and are typically encountered in Leaking Underground Fuel Tanks (LUFT) at garages or fuel depots. The second group (5)(6)(7)(8)(9)(10)) is representative of a large class of chlorinated hydrocarbon compounds (CHC). These analytes are often encountered as DNAPL (Dense Non-Aqueous The LOD, MDL, and PQL parameters were determined by taking appropriate replicate measurements.…”
Section: Laboratory Leslng Of Est 7100 Instrumentmentioning
confidence: 99%
“…BTEX (Benzene, Toluene, Ethylbenzene and Xylene) compounds (1-4) are important components of gasoline and are typically encountered in Leaking Underground Fuel Tanks (LUFT) at garages or fuel depots. The second group (5)(6)(7)(8)(9)(10)) is representative of a large class of chlorinated hydrocarbon compounds (CHC). These analytes are often encountered as DNAPL (Dense Non-Aqueous The LOD, MDL, and PQL parameters were determined by taking appropriate replicate measurements.…”
Section: Laboratory Leslng Of Est 7100 Instrumentmentioning
confidence: 99%
“…6 However, its use as a multicomponent, completely automated continuous emissions monitor is not documented in the literature.…”
Section: Introductionmentioning
confidence: 99%
“…Unfortunately, all of these approaches result in only a small portion of the original sample being injected onto the column, making them inadequate for the analysis of trace samples. A more efficient means of minimizing injection band duration has been developed by Sacks and co-workers. , In their technique, compounds in the gas phase are cryofocused onto metal tubes, followed by ballistic heating of the tube to ∼200 °C in a few milliseconds. The trapped compounds are rapidly vaporized and injected into the chromatographic column with a band duration on the order of 10 ms.…”
mentioning
confidence: 99%
“…A more efficient means of minimizing injection band duration has been developed by Sacks and co-workers. 13,[16][17][18][19][20][21][22][23][24][25] In their technique, compounds in the gas phase are cryofocused onto metal tubes, followed by ballistic heating of the tube to ∼200 °C in a few milliseconds. The trapped compounds are rapidly vaporized and injected into the chromatographic column with a band duration on the order of 10 ms.…”
mentioning
confidence: 99%
See 1 more Smart Citation