1999
DOI: 10.1117/12.359332
|View full text |Cite
|
Sign up to set email alerts
|

<title>Effects of rectangular microchannel aspect ratio on laminar friction constant</title>

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

3
45
0

Year Published

2005
2005
2020
2020

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 65 publications
(48 citation statements)
references
References 22 publications
3
45
0
Order By: Relevance
“…The Reynolds number at which the thermal behavior indicates a transition from laminar to turbulent flow has also differed widely in these studies. Possible reasons advanced to account for the deviation from classical theory have included surface roughness [4], electrical double layer [5] and aspect ratio [6] effects. The capability of Navier-Stokes equations to adequately represent the flow and heat transfer behavior in microchannels has been called into question in some of these studies.…”
Section: Introductionmentioning
confidence: 99%
“…The Reynolds number at which the thermal behavior indicates a transition from laminar to turbulent flow has also differed widely in these studies. Possible reasons advanced to account for the deviation from classical theory have included surface roughness [4], electrical double layer [5] and aspect ratio [6] effects. The capability of Navier-Stokes equations to adequately represent the flow and heat transfer behavior in microchannels has been called into question in some of these studies.…”
Section: Introductionmentioning
confidence: 99%
“…A commonly used analytical description of flow characteristics in microinjectors allowed us to design our devices. [27][28][29][30] Flow rate Q per applied pressure DP through a microchannel is given by…”
Section: Mems-based Injection Systemmentioning
confidence: 99%
“…28 Calculated steady-state flow rates per applied pressure for two different needle designs are reported in Table 1. The dynamic viscosity of water, m water = 10 23 N s m 22 at 20uC was used.…”
Section: Mems-based Injection Systemmentioning
confidence: 99%
“…It was shown that microfluidic-based systems have a great potential in application for single-cell analysis [1,2] and instant analyses or so called point-of-care (POC) diagnostics [3][4][5]. In this respect, microfluidics systems provide conditions that are comparable to in vivo conditions [1].…”
Section: Introductionmentioning
confidence: 99%
“…Microchannel geometry and surface texture are considered as the crucial factors in determining fluid flow through microchannels. These factors mainly depend on microfabrication techniques and fabrication processes of the microchannels [2][3][4].…”
Section: Introductionmentioning
confidence: 99%