2020
DOI: 10.2147/opth.s233884
|View full text |Cite
|
Sign up to set email alerts
|

<p>Hybrid 23/27 Gauge Vitrectomy – Combining the Charm of 27G with the Efficacy of 23G</p>

Abstract: Background: Minimally invasive transconjunctival sutureless vitrectomy (MIVS) has evolved into the standard of care, smaller incisions thought to result in lower ocular surface trauma and shorter times to recovery. The currently most relevant limitations in macular surgery may be light intensity and 27G instrument stability. Therefore, we thought to compare standard 23 and 27G vitrectomy with a hybrid technique using one 23G and two 27G ports regarding surgical times and short-term outcomes. Methods: This retr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0
1

Year Published

2020
2020
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 34 publications
0
3
0
1
Order By: Relevance
“…It has been suggested that longer vitrectomy times are expected with 27-gauge platforms due to the smaller radius of the cutter's lumen and limited fluid flow rates. 12,[15][16][17] However, several clinical studies have demonstrated similar operation times in 27-gauge vitrectomy compared to its 23-and 25-gauge counterparts. 3,18,19 In our study, 23-gauge surgeries actually lasted slightly longer at a mean of 39 mins compared to 27-gauge surgeries at a mean of 35 mins, although the difference was not statistically significant.…”
Section: Discussionmentioning
confidence: 99%
“…It has been suggested that longer vitrectomy times are expected with 27-gauge platforms due to the smaller radius of the cutter's lumen and limited fluid flow rates. 12,[15][16][17] However, several clinical studies have demonstrated similar operation times in 27-gauge vitrectomy compared to its 23-and 25-gauge counterparts. 3,18,19 In our study, 23-gauge surgeries actually lasted slightly longer at a mean of 39 mins compared to 27-gauge surgeries at a mean of 35 mins, although the difference was not statistically significant.…”
Section: Discussionmentioning
confidence: 99%
“…Ameliyat sırasında sklerotomi çaplarını değiştirmemek ve sonuçları iyileştirmek için bazı yazarlar, özel cerrahi ihtiyaçlara bağlı olarak farklı boyutlardaki küçük gauge vitrektomi aletlerini karıştırmayı düşünmüşlerdir. [45] Hibrit-gauge vitrektomi, bir vitrektomi vakası sırasında çok sayıda farklı gauge sklerotomi kullanımını içerir. Örneğin, hibrit 20/23G vitrektomi, 23G vitrektomi sırasında planlanmış veya büyütülmüş bir sklerotomi yoluyla 20G'lik bir alet yerleştirildiğinde gerçekleştirilir.…”
Section: Hibrid Gauge Ve Karma Gauge Vitrektomiunclassified
“…However, the stiffness and efficiency of the instruments, which are lost as 23G is avoided, remains another issue worth discussing. 14,15…”
mentioning
confidence: 99%
“…However, the stiffness and efficiency of the instruments, which are lost as 23G is avoided, remains another issue worth discussing. 14,15 To date, various efforts to optimize sutureless sclerotomy closure, including scleral wound hydration, application of bioadhesives and polyethylene glycolbased hydrogel bandage, cauterization of sclerotomy sites, wedge-shaped sclerotomies, transconjunctival plain gut tape procedure, scleral needling, refashioning of 23G sclerotomies, and hermetic closure, have been reported. 12,13,[16][17][18][19][20][21][22][23][24][25][26][27][28][29] Although these techniques offer bright perspectives for achieving closure of the sclerotomy, there may be potential limitations for cost and patient discomfort.…”
mentioning
confidence: 99%