2018 International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM) 2018
DOI: 10.1109/speedam.2018.8445244
|View full text |Cite
|
Sign up to set email alerts
|

Low Voltage Soft Open Point with Energy Storage: System Simulation and Prototype Preliminary Test Results

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2019
2019
2020
2020

Publication Types

Select...
3
3

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 14 publications
0
7
0
Order By: Relevance
“…Also, the cost of putting an ES system will be less, as ES is a must need for modern DNs due to the intermittent nature of connected DERs. SOP based on voltage source converter (VSC) along with bidirectional Dual active bridge (DAB) dc-dc converter with ES coupled in dc-link is considered for SOP+ES application in [28] and sizing of ES connected in the dc-link is discussed in [29]. DAB converter output voltage is controlled by one of the VSCs as it is responsible for the control of the dc-link voltage (u dc ).…”
Section: Sop+esmentioning
confidence: 99%
“…Also, the cost of putting an ES system will be less, as ES is a must need for modern DNs due to the intermittent nature of connected DERs. SOP based on voltage source converter (VSC) along with bidirectional Dual active bridge (DAB) dc-dc converter with ES coupled in dc-link is considered for SOP+ES application in [28] and sizing of ES connected in the dc-link is discussed in [29]. DAB converter output voltage is controlled by one of the VSCs as it is responsible for the control of the dc-link voltage (u dc ).…”
Section: Sop+esmentioning
confidence: 99%
“…Here, the standpoint is to present the test results of a full-scale LV prototype, rated for 15 kVA. The design key issues of the SOP were presented in [29], and will only partially be repeated here. The tests were performed in a laboratory environment, the GridLab laboratory at the HES-SO Valais (CH).…”
Section: Of 18mentioning
confidence: 99%
“…• A PQ mode [29]: In this mode, the reference values for the active power transferred through the SOP and the reactive powers are supplied to both SOP terminals. In this mode, the reference values need to be determined by an external control/optimization system with a control objective, e.g., the minimization of transformer loadings.…”
Section: Sop Control Modesmentioning
confidence: 99%
See 1 more Smart Citation
“…e "AC-DC-AC" operation mode of back-to-back VSC-HVDC provided the possibility of integration of ESS and VSC-MTDC [13]. SOP integrated with ESS is simulated, and the prototype was preliminarily tested [14]. Ji et al [15] compared and analyzed maximum hosting capacity of DG based on the conventional SOP and the SOP integrated with ESS in the distribution network.…”
Section: Introductionmentioning
confidence: 99%