2018
DOI: 10.1002/rcm.8112
|View full text |Cite
|
Sign up to set email alerts
|

Low‐temperature plasma‐probe mass spectrometry based method for determination of new psychoactive substances in oral fluid

Abstract: The proposed LTP-MS-based method was promising in forensic and on-site applications to curb the abuse of NPSs.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2020
2020
2021
2021

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 10 publications
(6 citation statements)
references
References 39 publications
(74 reference statements)
0
6
0
Order By: Relevance
“…Therefore, the use of an isotopicallylabeled IS is important to ensure quantification over a good dynamic range or to give a reference for the absence of ion suppression when screening for the presence of a particular analyte in a complex matrix. In the case of NPS analysis using AIMS, the dynamic range has been proven to stretch up to three to five orders of magnitude; in earlier literature, the method's detection has mostly focused on the lower end of the concentration range, which is of high interest when dealing with NPS in biological matrices (Bianchi et al, 2019;Nie et al, 2016;Nollet & Munjanja, 2019;Wang et al, 2018).…”
Section: Molecular Coverage Dynamic Range and True Unknownsmentioning
confidence: 99%
See 4 more Smart Citations
“…Therefore, the use of an isotopicallylabeled IS is important to ensure quantification over a good dynamic range or to give a reference for the absence of ion suppression when screening for the presence of a particular analyte in a complex matrix. In the case of NPS analysis using AIMS, the dynamic range has been proven to stretch up to three to five orders of magnitude; in earlier literature, the method's detection has mostly focused on the lower end of the concentration range, which is of high interest when dealing with NPS in biological matrices (Bianchi et al, 2019;Nie et al, 2016;Nollet & Munjanja, 2019;Wang et al, 2018).…”
Section: Molecular Coverage Dynamic Range and True Unknownsmentioning
confidence: 99%
“…The IS was added to the paper before analysis (Kennedy et al, 2018). Other sources, such as LTP and DESI, have been used to quantify cathinones and SCRAs in oral fluid, and LLOQs in the ng/ml range have been achieved (Bianchi et al, 2019;Wang et al, 2018). However, LTP-MS presented modest repeatability, and even though this was better with DESI-MS, the latter included a MEPS procedure that significantly increased the analysis time (15 min) and LLOQs were high (50-500 ng/ml).…”
Section: Quantificationmentioning
confidence: 99%
See 3 more Smart Citations