2021
DOI: 10.1109/jsyst.2020.2998059
|View full text |Cite
|
Sign up to set email alerts
|

Localized Protection of Radial DC Microgrids With High Penetration of Constant Power Loads

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
20
0
2

Year Published

2021
2021
2024
2024

Publication Types

Select...
8
1
1

Relationship

3
7

Authors

Journals

citations
Cited by 50 publications
(22 citation statements)
references
References 29 publications
0
20
0
2
Order By: Relevance
“…The various statistical Spatio-temporal methods were applied to detect FDIAs in smart grid. The procedures are leveraged the datum co-linearity which occur in the AMI measurements of the electrical power grid to prepare anticipation for the AMI observations of the grid, attaining to rapidly diagnose the presence of "bad data"; besides, a plan for FDIAs with several adversaries and an alone smart grid defender were presented in reference [31]. Two-game schemes have been investigated to consider the interplays among the attackers and the defender.…”
Section: B Literature Reviewmentioning
confidence: 99%
“…The various statistical Spatio-temporal methods were applied to detect FDIAs in smart grid. The procedures are leveraged the datum co-linearity which occur in the AMI measurements of the electrical power grid to prepare anticipation for the AMI observations of the grid, attaining to rapidly diagnose the presence of "bad data"; besides, a plan for FDIAs with several adversaries and an alone smart grid defender were presented in reference [31]. Two-game schemes have been investigated to consider the interplays among the attackers and the defender.…”
Section: B Literature Reviewmentioning
confidence: 99%
“…Resources in a Microgrid Most renewable sources are used in microgrids with lower power levels (around 200kW) and are connected with the main bus through power converters [28][29][30][31]. These systems are installed near the commercial and industrial sites for meeting the power demand.…”
Section: Integration Of Hybrid Biomass-solid Waste Energymentioning
confidence: 99%
“…The lack of effective protection strategy and the nature of DC faults make the protection of DC Microgrids a significant challenge for DC Microgrid implementations [10]. In the DC systems, due to the high rate and amplitude of fault current, the low cable impedance, the presence of power converters, and lack of zero-crossing point, the detection of a fault in the DC Microgrids is difficult [11]. Therefore, designing a fast, selective, and reliable protection strategy for reducing the cost and risk of DC Microgrids is crucial.…”
Section: Introductionmentioning
confidence: 99%