Ion Measurements in Physiology and Medicine 1985
DOI: 10.1007/978-3-642-70518-2_7
|View full text |Cite
|
Sign up to set email alerts
|

Lifetime of Neutral Carrier-Based Membranes in Aqueous Systems and Blood Serum

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
5
0

Year Published

1986
1986
2008
2008

Publication Types

Select...
3
2
1

Relationship

0
6

Authors

Journals

citations
Cited by 13 publications
(6 citation statements)
references
References 6 publications
1
5
0
Order By: Relevance
“…"Logarithm of the partition coefficient between water and octan-l-ol as determined by thin-layer chromatography (TLC). 6 A value of 11.6 has been reported in our earlier papers (21,22). More extensive investigations in the frame of this work revealed that it is originated in an impurity in the batch of TDDA used at that time.…”
Section: Resultssupporting
confidence: 52%
See 1 more Smart Citation
“…"Logarithm of the partition coefficient between water and octan-l-ol as determined by thin-layer chromatography (TLC). 6 A value of 11.6 has been reported in our earlier papers (21,22). More extensive investigations in the frame of this work revealed that it is originated in an impurity in the batch of TDDA used at that time.…”
Section: Resultssupporting
confidence: 52%
“…The ionophores presented here have been designed to exhibit a high lipophilicity (see Table I). This is necessary to cope with the high lipophilic character of biological samples which will promote the extraction of low molecular weight components (21).…”
Section: Resultsmentioning
confidence: 99%
“…0.1 ng) [9]. With the dissolution of membrane components, the membrane resistance increases, the response slope of the ISE decreases, and the membrane selectivity can drop below a critical value or eventually be lost completely [3,4,7].…”
Section: Introductionmentioning
confidence: 97%
“…In general, the highly hydrophobic nature of the membrane components minimize their partition into an aqueous electrolyte while the high concentration of anionic or cationic sites in the membrane prevent the partitioning of whole bathing salts, such as KCl, into the membrane [2]. However, the relevant partition coefficients are orders of magnitude less advantageous in membrane/serum systems [7]. Consequently, with decreasing membrane dimensions, and extended use in large volumes of biological samples, like whole blood, the dissolution of membrane components can limit the sensor lifetime.…”
Section: Introductionmentioning
confidence: 97%
See 1 more Smart Citation