Abstract: Laparoscopic splenectomy (LS) is a preferred choice, especially for hematologic diseases. We present the advantages of the use of LigaSure (energy-based equipment that works by applying a precise amount of bipolar energy and pressure to the tissue, achieving a permanent seal) for achieving a precise hemostasis, thus making the LS easier. We have performed LS using LigaSure on 10 patients (4 female, 6 male; mean age, 36 years [range, 16-58]) between December 2002 and August 2003. All patients had ITP. There wer… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
16
0

Year Published

2007
2007
2015
2015

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 27 publications
(17 citation statements)
references
References 23 publications
1
16
0
Order By: Relevance
“…Yüney et al [124] performed LS for 10 patients with ITP using LigaSure TM for hilar vessel sealing. The mean blood loss was 60 ml, and the average operating time was 93 min, without any conversions or complications in the postoperative period (LoE 4).…”
Section: Technical Aspects Of Laparoscopic Splenectomymentioning
confidence: 99%
See 1 more Smart Citation
“…Yüney et al [124] performed LS for 10 patients with ITP using LigaSure TM for hilar vessel sealing. The mean blood loss was 60 ml, and the average operating time was 93 min, without any conversions or complications in the postoperative period (LoE 4).…”
Section: Technical Aspects Of Laparoscopic Splenectomymentioning
confidence: 99%
“…Use of the endovascular stapler is reported to shorten and facilitate hilar dissection compared with the former techniques of ligation or clipping (LoE 4) [121,123]. Recently, electrothermal bipolar vessel sealer (LigaSure TM ) or ultrasonic coagulating shears (Ultracision Harmonic Scalpel TM , Ethicon Endosurgical, Cincinnati, OH) have been used for dissection of smaller polar vessels and the small gastric vessels (LoE 4) [124], vesselcontaining tissue (LoE 4) [39,125,126], or even the greater hilar vessels (LoE4) [127]. Romano et al [128,129] reported the safe use of LigaSure TM for hilar vessels with a diameter up to 7 mm in patients with normal-sized to slightly enlarged spleens as well as lower blood loss, shorter operative time, and even lower costs than with other techniques (LoE 2b).…”
Section: Technical Aspects Of Laparoscopic Splenectomymentioning
confidence: 99%
“…As the increased cost of laparoscopic splenectomy is mostly driven by the price of tools, especially disposable ones, they suggest reusing them. Yünney and Hamamci confirm in practice, with results of bacteriological studies, that preparation tools, trocars and the LigaSure device can be successfully re-sterilized and re-used [16,39]. The cost of a single application of LigaSure coagulation is 1980 zlotys.…”
Section: Discussionmentioning
confidence: 52%
“…The cost of a single application of LigaSure coagulation is 1980 zlotys. Considering 4 or 5-time usage of LigaSure coagulation, according to Yüney's publication, the cost for a single procedure would be 396 zlotys [39]. Unfortunately, according to American and EU standards such a solution cannot be applied.…”
Section: Discussionmentioning