1995
DOI: 10.1016/1044-0305(95)00484-u
|View full text |Cite
|
Sign up to set email alerts
|

Isotope ratios and abundance sensitivity obtained with an inductively coupled plasma-time-of-flight mass spectrometer

Abstract: Isotope ratios and abundance sensitivities have been determined with an inductively coupled plasma-time-of-flight mass spectrometer (ICP-TOFMS). Abundance sensitivities are at least in the 10(6) range for low abundance ions that precede high abundance ions. Three methods of detection for isotope-ratio measurement have been compared. The three systems involve gated detection followed by analog integration, analog averaging, or ion counting. Gated ion counting offers excellent precision-between 0. 64 and 1. 00% … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
40
0

Year Published

2000
2000
2017
2017

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 36 publications
(41 citation statements)
references
References 17 publications
(11 reference statements)
1
40
0
Order By: Relevance
“…In a later study, Hieftje and coworkers investigated the ability of ICP±oa-TOFMS to measure isotope ratios precisely and to yield abundance sensitivity (the dynamic range in measurable signal intensities for isotopes with adjacent mass numbers) (Myers et al, 1995c). Good FIGURE 32.…”
Section: Elemental Mass Spectrometrymentioning
confidence: 99%
“…In a later study, Hieftje and coworkers investigated the ability of ICP±oa-TOFMS to measure isotope ratios precisely and to yield abundance sensitivity (the dynamic range in measurable signal intensities for isotopes with adjacent mass numbers) (Myers et al, 1995c). Good FIGURE 32.…”
Section: Elemental Mass Spectrometrymentioning
confidence: 99%
“…Furthermore, alignment of the main velocity of the ions with the direction of the flight tube in aa-TOFMS eliminates turnaround-time errors. Despite the apparent advantages and limitations of these competitive geometries, the experimental performance of both designs is similar and comparable with the figures of merit from other ICPMS platforms (16)(17)(18)(19)(20). Commonly, ICP-TOFMS systems achieve elemental sensitivities of 10 6 -10 7 cps/ppm/isotope and detection limits of 0.1-10 ppt for all elements and isotopes of interest, measured concurrently.…”
Section: Tofms With Plasma Sourcesmentioning
confidence: 80%
“…The improvement in isotope-ratio precision compared with the MCP/ phosphor screen detection system is attributed to the directcharge integration and on-line readout of the IonCCD camera system. Isotope-ratio precision for ICP-TOFMS is typically ≥0.05% RSD [33][34][35][36] and requires seconds to minutes of acquisition time, depending on wheteher analog detection or ion counting is used. For the three elements studied at 1-ppm concentration, isotope-ratio precision is comparable to that for TOFMS but were obtained with no more than 1 s integration time.…”
Section: Eumentioning