Frontiers of Radiation Therapy and Oncology 1997
DOI: 10.1159/000061145
|View full text |Cite
|
Sign up to set email alerts
|

IORT Novac7: A New Linear Accelerator for Electron Beam Therapy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
3
0
1

Year Published

2006
2006
2023
2023

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 0 publications
1
3
0
1
Order By: Relevance
“…However, for 3 MeV and 5 MeV electron beams the dose-per-pulse values measured at z ref were almost independent of the applicator diameter (5.1 and 12 mGy/pulse for 3 MeV and 5 MeV, respectively). This is also in good agreement with results given in the literature [15]. …”
Section: Comparison Of Different Methodssupporting
confidence: 93%
See 2 more Smart Citations
“…However, for 3 MeV and 5 MeV electron beams the dose-per-pulse values measured at z ref were almost independent of the applicator diameter (5.1 and 12 mGy/pulse for 3 MeV and 5 MeV, respectively). This is also in good agreement with results given in the literature [15]. …”
Section: Comparison Of Different Methodssupporting
confidence: 93%
“…This trend was not observed for 3 MeV and 5 MeV electrons. However, Fantini et al [15] have reported analogous findings. The constancy of the dose-per-pulse value with decreasing applicator diameter may be due to the absorption of low-energy scattered electrons before they reach the z ref .…”
Section: Discussionmentioning
confidence: 81%
See 1 more Smart Citation
“…In principle, IORT can be applied using electrons of a linear accelerator situated in the operating theatre or nearby [ 4 ] or of special electron accelerators like Novac7™ [ 5 ] or Mobetron™ [ 6 ]. Another possibility is the application of brachytherapy using a Ir-192 source guided by needles or plastic tubes within silicone flaps which are very useful to maintain the irradiation geometry [ 7 ].…”
Section: Introductionmentioning
confidence: 99%
“…Akcelerator Novac składa się z konsoli sterującej oraz ruchomej jednostki terapeutycznej zawierającej strukturę przyspieszającą elektrony, połączoną ze źródłem mikrofal i modulatorem za pomocą elastycznego falowodu. Głowica akceleratora charakteryzuje się sześcioma stopniami swobody, a cały system waży mniej niż 650 kg [11,12] Akceleratory stosowane do IORT są w stanie wygenerować wiązkę promieniowania elektronowego najczęściej o energiach w zakresie od 4 MeV do 12 MeV, dla których przykładowe rozkłady głębokościowe przedstawiono na rysunku 2. Wybór odpowiedniej energii umożliwia dopasowanie głębokości penetracji promieniowania do grubości napromienianej tkanki, tak aby izodozą terapeutyczną objąć wyznaczoną objętość.…”
Section: Aparatura Do Ioertunclassified