2020
DOI: 10.1007/s10762-020-00726-x
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of the Frequency Double-Multiplication Effect in a Sub-THz Gyrotron

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
2
0
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 21 publications
(3 citation statements)
references
References 14 publications
0
2
0
1
Order By: Relevance
“…The structure was mounted at the end of the waveguide insert inside a compact superconducting magnet. The magnetic field was varied from 0 to 3 T, while the radiation frequency was fixed at 526 GHz.We used the second harmonic of the sub-THz gyrotron operating at 263 GHz as the exciting radiation [ 28 ], providing highly stable intensity. A gapless HgCdTe epilayer was exploited as the detector, with sensitivity comparable to an InSb hot electron bolometer [ 29 ].…”
Section: Methodsmentioning
confidence: 99%
“…The structure was mounted at the end of the waveguide insert inside a compact superconducting magnet. The magnetic field was varied from 0 to 3 T, while the radiation frequency was fixed at 526 GHz.We used the second harmonic of the sub-THz gyrotron operating at 263 GHz as the exciting radiation [ 28 ], providing highly stable intensity. A gapless HgCdTe epilayer was exploited as the detector, with sensitivity comparable to an InSb hot electron bolometer [ 29 ].…”
Section: Methodsmentioning
confidence: 99%
“…Это обусловлено, с одной стороны, неэквидистантностью спектра мод цилиндрических волноводов, типично используемых в гиротронах, а с другойбыстрым спаданием коэффициентов связи с увеличением номера гармоники. В частности, проведенные в [7,8] измерения мощности для гиротрона с рабочей частотой 263 GHz показали, что значения КНТ на второй циклотронной гармонике составили 10 −4 (т. е. около 0.01% от мощности излучения на первой гармонике), а для третьей -около 10 −6 (0.0001%).…”
unclassified
“…This is caused, on the one side, by an unequal spacing of the cylindrical waveguide spectrum modes and, on the other side, by a rapid decrease in the coupling coefficients with increasing harmonic number. For instance, presented in [7,8] power measurements for the gyrotron with operating frequency of 263 GHz showed that the NTC value at the second cyclotron harmonic was 10 −4 (i. e. about 0.01% of the first-harmonic radiation power) while that at the third cyclotron harmonic was about 10 −6 (0.0001%).…”
mentioning
confidence: 99%