2015
DOI: 10.1016/j.energy.2015.09.076
|View full text |Cite
|
Sign up to set email alerts
|

INVELOX with multiple wind turbine generator systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
22
0
1

Year Published

2017
2017
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 55 publications
(25 citation statements)
references
References 5 publications
0
22
0
1
Order By: Relevance
“…In addition, the cut‐in and cut‐out limits are stretched out by the IWT that causes creating power even at low speeds, for example, 1–2 m s −1 . [ 7,9 ] The IWT yield power is characterized by Equation (2). [ 9 ] PWT IWT(t)=(0 t : V Cut‐in ‐IWT Vt and V Cut‐out‐IWT Vt0.5×ρIWT×AIWT×ηnormalWIWT×Kp×false(Vt×SRfalse)3 t : VCut‐in‐IWT Vt V Cut‐out‐IWT)…”
Section: Problem Modelingmentioning
confidence: 99%
See 1 more Smart Citation
“…In addition, the cut‐in and cut‐out limits are stretched out by the IWT that causes creating power even at low speeds, for example, 1–2 m s −1 . [ 7,9 ] The IWT yield power is characterized by Equation (2). [ 9 ] PWT IWT(t)=(0 t : V Cut‐in ‐IWT Vt and V Cut‐out‐IWT Vt0.5×ρIWT×AIWT×ηnormalWIWT×Kp×false(Vt×SRfalse)3 t : VCut‐in‐IWT Vt V Cut‐out‐IWT)…”
Section: Problem Modelingmentioning
confidence: 99%
“…[ 8 ] As a result, the IWT's capacity to generate power with two generators operation is 1.5 times higher than single IWT, and three generators operation is 1.7 times higher than two generators operation. [ 9 ] Apart from high‐power generation with multiple structures of IWT, due to reducing the uncertainty of generator problems, using multigenerators at the same time, the reliability of the electrical network will be increased. Moreover, this structure is usable for various speeds, places, and applications because of the low threshold speed and scalability.…”
Section: Introductionmentioning
confidence: 99%
“…Allaei and Andreopoulos (2014) have been the first to present on-field measurements thus demonstrating that INVELOX can enhance the daily energy production ratio. In their following works (Allaei, 2012;Allaei and Andreopoulos, 2014;Allaei et al, 2015), they have also studied the flux within and outside of the prototype by performing numerical simulations, also varying the number of turbines within the Venturi section. Nevertheless, in literature, there are few evidences of analysis of the INVELOX geometry (Anbarsooz et al, 2017).…”
Section: Introductionmentioning
confidence: 99%
“…With this modification, the VAWT could be not only operated in omnidirectional winds but also exhibited augmented wind energy. In addition to these approaches, various other methods have been developed to augment the performance of the VAWT, such as increasing the height of the installed location of the wind turbine, [18][19][20] utilizing the wind augmented by the space between buildings, 21 installing a wind collector on the roof of buildings 22,23 .…”
Section: Introductionmentioning
confidence: 99%