Abstract:Outdoor thermal comfort affects the health of the people and the quality of life in urban areas. This is the reason why in the past few years different mitigation strategies for the microclimate have been studied and examined. These strategies depend on those passive factors characterizing the urban setting that are able to affect the values of local meteorological variables, as the limit surfaces of the urban space (parterre and façades of the buildings). This paper examines the Cloister by Giuliano da Sangallo, which is part of the Faculty of Engineering of Sapienza University of Rome. The case study compares the present configuration of the Cloister with four other configurations characterized by some vegetation and materials with a high albedo by taking into consideration the PMV (Predicted Mean Vote) model. Microclimatic variables are calculated through numerical simulations performed by the ENVI-met software. Such a comparison is performed during a typical summer day. While examining the results it can be noticed how the strategy presenting the best results is the one with some vegetation, whereas the materials with a high albedo improve the microclimate if applied on surfaces characterized by a high sky view factor. OPEN ACCESSSustainability 2015, 7 9013
Abstract:Proper lighting is vital to improve, from an artistic point of view, the surface expanse and decorative detailing of architectural heritage buildings considered valuable. When properly lit, monumental buildings can become to onlookers an essential part of the city. Nowadays, for design planners dealing with the improvement of buildings, whose architectural design should be valorized, the real challenge is to combine the lighting artistic requirements with scrupulous economic management in order to limit the energy demand and to respect the environment. For these reasons, this case study examines the lighting of the monumental façade and the cloister of St. Peter in Chains situated in the Faculty of Engineering of Sapienza University of Rome. The present lighting installation, characterized by metal halides, compact fluorescent and halogen lamps, is compared with an alternative scenario presenting LED lamps and scenographic lighting of the monumental façade. Such comparison is based on the evaluation of the lighting levels for different visual tasks and on energy and maintenance issues; the first analysis was performed through the software DIALux Evo 4.0, whereas the second was performed using ecoCALC. This study leads to the conclusion that the lighting levels of the solution OPEN ACCESSSustainability 2015, 7 10771 presenting LED lamps are better than those of the present solution, and they comply with current standards. Finally, the higher costs of LED lamp installations and the scenographic lighting of the monumental façade are balanced by lower maintenance costs, with a payback period of seven years.
Abstract:The goal set by the EU of quasi-zero energy buildings is not easy to reach for a country like Italy, as it holds a wide number of UNESCO sites and most of them are entire historical old towns. This paper focuses on the problem of the improvement of energy performance of historical Italian architecture through simple interventions that respect the building without changing its shape and structure. The work starts from an energy analysis of a building located in the historic center of Tivoli, a town close to Rome. The analysis follows the recommendations of the UNI TS 11300-Part1, which indicates how to evaluate the energy consumptions. The calculations were performed only on the building envelope, based on passive solutions and alternatives. Four passive strategies were examined and applied based on the location of the building and the non-alteration of the structure and the landscape. The obtained results impacted positively on the energy performance of the building: the annual energy saving reached a maximum value of 25%. This work shows how it is possible to improve the energy performance of an existing building achieving a significant energy saving with the respect of the building architecture, shape, function and the surrounding landscape.
The energy refurbishment of the existing building heritage is one of the pillars of Italian energy policy. Aiming for energy efficiency and energy saving in end uses, there are wide and diversified improvement strategies, which include interventions on the building envelope and Heating, Ventilation, and Air Conditioning (HVAC) systems, with the introduction of renewable energy sources. The research aims at evaluating the building energy consumptions and Indoor Environmental Quality (IEQ), varying the airflow rates handled by the HVAC system. A Case Study (the Aula Magna of a university building) is analysed; an in-situ monitoring campaign was carried out to evaluate the trend of some environmental parameters that are considered to be significant when varying the external airflow rates handled by the HVAC system. Additionally, dynamic simulations were carried out, with the aim of evaluating the energy savings coming from the airflow rates reduction. The results of this case study highlight the opportunity to achieve significant energy savings, with only slight variations in IEQ; a 50% reduction in airflow rate would decrease energy consumption by up to 45.2%, while increasing the carbon dioxide concentration from 545 ppm to 655 ppm, while the Particulate Matter and Total Volatile Organic Compounds increase is insignificant.
While planning a double-hole road tunnel with a length higher than one km, it is important to pay attention to the safety factor if an accident occurs. If there is a power outage, in order to avoid critical situations that could jeopardize the safety of the people present (facilitating the stream coming out from the tunnel and the arrival of the emergency personnel), it is really important to guarantee uninterrupted lighting of roadways, mandatory emergency lay-bys, and ways of escape. Uninterrupted service of the lighting systems supply must be guaranteed, in accordance with the current regulations, through the exertion of UPS (Uninterruptible Power Supply) and power units. During tunnel construction, such devices represent a cost that must be amortized. In this case study, which takes into consideration a section of a road tunnel characterized by emergency lay-bys and ways of escape, emergency and security lighting were planned and installation and management costs were evaluated. The goal of this research was the creation of a cash flow thanks to the energy generated by photovoltaic panels, in a way that the service life of the system (25 years) coincided with the amortization of the costs of the backup electrical equipment installation (complying with the regulations). The possibility of over-dimensioning the UPS and providing it with a proper OPEN ACCESS Sustainability 2015, 7 9810 photovoltaic panel surface (235 kWp) to generate and exchange electric energy with the grid was taken into consideration.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.