2017
DOI: 10.1007/s10337-017-3295-1
|View full text |Cite
|
Sign up to set email alerts
|

Introduction of Fullerene as a New Carrier in Electromembrane Extraction for the Determination of Ibuprofen and Sodium Diclofenac as Model Acidic Drugs in Real Urine Samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(4 citation statements)
references
References 49 publications
0
4
0
Order By: Relevance
“…These solvents have relatively high polarity (π*), strong hydrogen-bond acidity (α), and basicity (β) which makes them suitable for the extraction of acidic compounds. [34][35][36] Among the tested solvents, 1-octanol, due to its suitable viscosity and low vapor pressure, provided a stable membrane for the EME of ETX. [37] 3.1.…”
Section: Supported Liquid Membrane (Slm) Compositionmentioning
confidence: 99%
“…These solvents have relatively high polarity (π*), strong hydrogen-bond acidity (α), and basicity (β) which makes them suitable for the extraction of acidic compounds. [34][35][36] Among the tested solvents, 1-octanol, due to its suitable viscosity and low vapor pressure, provided a stable membrane for the EME of ETX. [37] 3.1.…”
Section: Supported Liquid Membrane (Slm) Compositionmentioning
confidence: 99%
“…At the same time Atarodi et al (2017) developed EME combined with high-performance liquid chromatography (HPLC) coupled with ultraviolet (UV) detection for analysis of ibuprofen and sodium diclofenac in urine samples (Atarodi et al, 2017). Also, Akkaya (2017) investigated a combination of slotted quartz tube attached to flame atomic absorption spectrometry and stearic acid-coated magnetite nanoparticle-based SPME for the determination of ultratrace amounts of cadmium in urine samples.…”
Section: Urinementioning
confidence: 99%
“…EME refers to the receiving solution of charged targets by the supported liquid membrane in electric field. Recently, many novel membrane materials have been developed to improve extraction performance of EME, including combined materials, polymer inclusion membranes, , and gel membranes. , Particularly, to save the time for dried blood tests, Breadmore’s group developed an in-transit EME method to pretreat sample on the way to the laboratory, which showing potential in point-of-care tests …”
Section: Energy Exchange Accelerationmentioning
confidence: 99%