2021
DOI: 10.1002/bmc.5105
|View full text |Cite
|
Sign up to set email alerts
|

Recent applications of microextraction sample preparation techniques in biological samples analysis

Abstract: Analysis of biological samples is affected by interfering substances with chemical properties similar to those of the target analytes, such as drugs. Biological samples such as whole blood, plasma, serum, urine and saliva must be properly processed for separation, purification, enrichment and chemical modification to meet the requirements of the analytical instruments. This causes the sample preparation stage to be of undeniable importance in the analysis of such samples through methods such as microextraction… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 22 publications
(4 citation statements)
references
References 232 publications
(213 reference statements)
0
4
0
Order By: Relevance
“…Nitrogen gas adsorbents at -196 ° C in an autonomous volume device from micromeritics were used to analyze the geometric characteristics of carbon-based composites (model ASAP 2010). The materials (60–100 mg) were caused by trauma at 120°C overnight (16 hrs) under suction (compression 10-2 Pa) before Nitrogen adsorption [21]. The A BET , apparent surface area, was calculated from nitrogen gas adsorbate in the p/p0 region of the adsorbent plot, which guarantees an optimistic intercept on the BET plot’s ordinates (C greater than zero) and a linear rise of n ads (2-p/ p 0 ) with p/ p 0 .…”
Section: Methodsmentioning
confidence: 99%
“…Nitrogen gas adsorbents at -196 ° C in an autonomous volume device from micromeritics were used to analyze the geometric characteristics of carbon-based composites (model ASAP 2010). The materials (60–100 mg) were caused by trauma at 120°C overnight (16 hrs) under suction (compression 10-2 Pa) before Nitrogen adsorption [21]. The A BET , apparent surface area, was calculated from nitrogen gas adsorbate in the p/p0 region of the adsorbent plot, which guarantees an optimistic intercept on the BET plot’s ordinates (C greater than zero) and a linear rise of n ads (2-p/ p 0 ) with p/ p 0 .…”
Section: Methodsmentioning
confidence: 99%
“…There are several extraction/microextraction techniques that have been developed, including SPME, SPE, IT-SPME, MEPS, SBSE, Non-fiber SPME, and DSPME. The broad applicability and development of these techniques are thoroughly covered in our previous review paper (Daryanavard et al 2021 ). Some of the developed MIP-based extraction approaches are widely covered in the following sections.…”
Section: Mip In Bioanalysismentioning
confidence: 99%
“…This field has expanded quickly in recent years, providing versatile tools for the separation or detection of numerous chemical compounds or even macromolecules and cell domains, opening a wide range of applications in different branches of analytical chemistry, pharmaceutical analysis, forensic science, food control, environmental safety, and quite recently in drug delivery or theranostics. The application capabilities of molecularly imprinted materials in various fields were discussed comprehensively in numerous reviews that were published in the last few years [ 35 , 36 , 37 , 38 , 39 , 40 , 41 , 42 , 43 , 44 , 45 , 46 , 47 , 48 , 49 , 50 , 51 , 52 , 53 , 54 , 55 , 56 , 57 , 58 , 59 , 60 , 61 , 62 , 63 , 64 , 65 , 66 , 67 , 68 ].…”
Section: Introductionmentioning
confidence: 99%