2007
DOI: 10.1016/j.atmosenv.2006.11.040
|View full text |Cite
|
Sign up to set email alerts
|

Intercomparison of two different thermal-optical elemental carbons and optical black carbon during ABC-EAREX2005

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
16
0
3

Year Published

2008
2008
2013
2013

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 27 publications
(19 citation statements)
references
References 23 publications
0
16
0
3
Order By: Relevance
“…BC and EC are two carbon fractions typically defined by their measurement technique: BC is measured optically while EC is obtained from thermal and thermaloptical methods. According to the EPA Report to Congress on Black Carbon (http://www.epa.gov/blackcarbon/), about 70 % of recent studies (year 2000 or later) that compared ambient BC and EC measurements in a wide variety of environments reported consistently obtaining a high correlation with an average of R = 0.86 ± 0.11 (Allen et al, 1999;Bae et al, 2007;Hitzenberger et al, 2006;Sahu et al, 2009;Miyazaki et al, 2008;Husain et al, 2007;Hagler et al, 2007), while the other 30 % report very low BC : EC ratios (∼0.5) and very high BC : EC ratios (∼2) (Chow et al, 2009; Babich et al, 2000;Jeong et al, 2004;Lim et al, 2003). These inter-comparison data are based on ambient measurements and not on source measurements.…”
Section: Hyytiälä Smear II (Station For Measuring Forestmentioning
confidence: 99%
“…BC and EC are two carbon fractions typically defined by their measurement technique: BC is measured optically while EC is obtained from thermal and thermaloptical methods. According to the EPA Report to Congress on Black Carbon (http://www.epa.gov/blackcarbon/), about 70 % of recent studies (year 2000 or later) that compared ambient BC and EC measurements in a wide variety of environments reported consistently obtaining a high correlation with an average of R = 0.86 ± 0.11 (Allen et al, 1999;Bae et al, 2007;Hitzenberger et al, 2006;Sahu et al, 2009;Miyazaki et al, 2008;Husain et al, 2007;Hagler et al, 2007), while the other 30 % report very low BC : EC ratios (∼0.5) and very high BC : EC ratios (∼2) (Chow et al, 2009; Babich et al, 2000;Jeong et al, 2004;Lim et al, 2003). These inter-comparison data are based on ambient measurements and not on source measurements.…”
Section: Hyytiälä Smear II (Station For Measuring Forestmentioning
confidence: 99%
“…The most prevalent on-line techniques are bulk aerosol mass spectrometers, single particle mass spectrometers, and thermo-optical (Bae et al, 2007;Canagaratna et al, 2007;Murphy, 2007). Although these techniques are useful for quantification of bulk organic matter, they have limited application for molecular level understanding of organic aerosol.…”
Section: R C Moffet Et Al: Microscopic Characterization Of Carbonamentioning
confidence: 99%
“…이에 고산에서는 PM 2.5 중 OC와 EC의 장거리 수송 및 계절적 영향을 살펴 보기 위한 연구가 여러 차례 수행되었다 (Batmunkh et al, 2011;Lim et al, 2010;Lee et al, 2008;Moon et al, 2008;Bae et al, 2007;Lee et al, 2007;Song et al, 2006;Han et al, 2005;Shin et al, 2002;Kim et al, 1998;Lee et al, 1997). 대부분 약 24시간 동안 석영 필터에 시료를 포집한 후에 탄소 분석을 하였 으며 (Lim et al, 2010;Lee et al, 2008;Moon et al, 2008;Han et al, 2005;Shin et al, 2002;Kim et al, 1998;Lee et al, 1997), 준실시간으로 분석한 경우에도 단기간 동안의 집중측정이 대부분이었다 (Batmunkh et al, 2011;Bae et al, 2007;Lee et al, 2007;Song et al, 2006). 필터팩을 이용해 시료 채취시를 할 경우 에는 긴 시간 동안 포집된 반휘발성 화학물질들 Malaguti et al, 2013;Kang et al, 2010) (Chow et al, 2001).…”
Section: 고산 측정소는 동아시아 대륙의 풍하지역에 위치unclassified