2015
DOI: 10.1016/j.bios.2015.06.056
|View full text |Cite
|
Sign up to set email alerts
|

Integrated platform with magnetic purification and rolling circular amplification for sensitive fluorescent detection of ochratoxin A

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
16
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 34 publications
(16 citation statements)
references
References 37 publications
(32 reference statements)
0
16
0
Order By: Relevance
“…Using an optimal RCA template evolved from in vitro selection, the detection sensitivity of a reduced graphene oxide‐based method can be significantly improved . In contrast with aptamer recognition‐induced primer immobilization or release, some researchers made use of aptamer‐target recognition to inhibit the functions of primers, and then impede RCA reaction, leading to a decrease in scanometric or fluorescent intensities . Aptamer recognition‐induced release of primer for RCA assay is relatively facile and can be easily coupled with other methods for target detection.…”
Section: Rca With Functional Nucleic Acidsmentioning
confidence: 99%
“…Using an optimal RCA template evolved from in vitro selection, the detection sensitivity of a reduced graphene oxide‐based method can be significantly improved . In contrast with aptamer recognition‐induced primer immobilization or release, some researchers made use of aptamer‐target recognition to inhibit the functions of primers, and then impede RCA reaction, leading to a decrease in scanometric or fluorescent intensities . Aptamer recognition‐induced release of primer for RCA assay is relatively facile and can be easily coupled with other methods for target detection.…”
Section: Rca With Functional Nucleic Acidsmentioning
confidence: 99%
“…Since the magnetic carriers have got functional groups like ion exchanger ligands, hydrophobic groups or bio-polymeric agents, the purification can be done in one step without utilizing centrifuges, filters or other equipment 36 . For this purpose, carboxyl-MNPs were prepared by solve-thermal protocol 37 and were surface modified via the RCA primer containing the specific aptamer related to OTA 38 .…”
Section: Detection Of Ochratoxin a By Combining Magnetic Nanoparticlementioning
confidence: 99%
“…In the presence of OTA, fluorescent particles would be partially released due to the competitive binding between OTA and specific OTA aptamer. For wider linear range and higher sensitivity, Yao et al [89] developed a biosensor for the OTA measurement integrating magnetic nanoparticles with rolling circular amplification (RCA). Magnetic nanoparticles were used to decrease the signal via efficient separation, and RCA was used for the signal amplification.…”
Section: Applicationsmentioning
confidence: 99%