Instrument reflections and scene amplitude modulation in a polychromatic microwave quadrature interferometer

Abstract: A polychromatic microwave quadrature interferometer has been characterized using several laboratory plasmas. Reflections between the transmitter and the receiver have been observed, and the effects of including reflection terms in the data reduction equation have been examined. An error analysis which includes the reflections, modulation of the scene beam amplitude by the plasma, and simultaneous measurements at two frequencies has been applied to the empirical database, and the results are summarized. For ref… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0

Year Published

2004
2004
2009
2009

Publication Types

Select...
4
3

Relationship

1
6

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 4 publications
0
6
0
Order By: Relevance
“…A polychromatic quadrature interferometer is used that operates simultaneously at 70, 90, and 110 GHz. 18 This instrument is positioned near the nozzle entrance, 0.33 m downstream from the choke magnet. The spatial resolution for this interferometer is 0.015 m, with a minimum sensitivity of 10 16 m −3 over the 1 m path length.…”
Section: A Plasma Diagnosticsmentioning
confidence: 99%
See 1 more Smart Citation
“…A polychromatic quadrature interferometer is used that operates simultaneously at 70, 90, and 110 GHz. 18 This instrument is positioned near the nozzle entrance, 0.33 m downstream from the choke magnet. The spatial resolution for this interferometer is 0.015 m, with a minimum sensitivity of 10 16 m −3 over the 1 m path length.…”
Section: A Plasma Diagnosticsmentioning
confidence: 99%
“…Calibration of all interferometer systems was conducted daily, providing estimates of random and systematic error due to beam reflection and detector voltage drift. 18 Interferometer density measurements are performed in two ways. Independent density profiles are obtained by vertical translation of the polychromatic interferometer over several plasma shots.…”
Section: A Plasma Diagnosticsmentioning
confidence: 99%
“…A polychromatic quadrature interferometer is used which operates simultaneously at 70 GHz, 90 GHz and 110 GHz. 9 This instrument is positioned near the nozzle entrance, about 0.5 m downstream from the plasma source. The spatial resolution for this interferometer is typically 0.015 m, with a minimum sensitivity of 10 16 m -3 over the 0.1 m pathlength.…”
Section: Measurementsmentioning
confidence: 99%
“…This interferometer has been used to measure the electron density in the VASIMR VX-20 device. 2,3 The VX-20 experiment employs a helicon discharge in helium which produces a flowing plasma with a high degree of ionization. We discuss measurements at a location where the plasma diameter of ϳ3 cm is comparable to the beam size.…”
Section: Methodsmentioning
confidence: 99%