2019
DOI: 10.1016/j.microc.2018.12.018
|View full text |Cite
|
Sign up to set email alerts
|

Innovative ultra-sensitive spectrofluorimetric method for nanogram detection of doripenem monohydrate in human plasma, urine and pharmaceutical formulation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
28
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6

Relationship

6
0

Authors

Journals

citations
Cited by 16 publications
(29 citation statements)
references
References 17 publications
1
28
0
Order By: Relevance
“…The coloured product formed from the reaction between SPEC and NBD-Cl was pH dependent and was produced using 0.1 M borate buffer (pH 9.2 ± 0.2) with a volume of 1.5 ± 0.25 ml giving the most suitable buffer conditions (Figure 3a and Supporting Information Figure S1). [23,26] Expanding the pH range of the 0.1 M borate buffer to values higher than 9.5 caused a decrease in relative fluorescence intensity (RFI) due to increase in hydroxide group concentration that prevented the reaction between SPEC and NBD-Cl; this result concurred with those of previously published studies. [12,23,26] FIGURE 2 (a) Absorption and (b) excitation (460 nm) and emission (530 nm) spectra of the reaction product formed between NBD-Cl and SPEC (2 μg ml −1 and 150 ng ml −1 respectively)…”
Section: Effect Of Phsupporting
confidence: 89%
See 3 more Smart Citations
“…The coloured product formed from the reaction between SPEC and NBD-Cl was pH dependent and was produced using 0.1 M borate buffer (pH 9.2 ± 0.2) with a volume of 1.5 ± 0.25 ml giving the most suitable buffer conditions (Figure 3a and Supporting Information Figure S1). [23,26] Expanding the pH range of the 0.1 M borate buffer to values higher than 9.5 caused a decrease in relative fluorescence intensity (RFI) due to increase in hydroxide group concentration that prevented the reaction between SPEC and NBD-Cl; this result concurred with those of previously published studies. [12,23,26] FIGURE 2 (a) Absorption and (b) excitation (460 nm) and emission (530 nm) spectra of the reaction product formed between NBD-Cl and SPEC (2 μg ml −1 and 150 ng ml −1 respectively)…”
Section: Effect Of Phsupporting
confidence: 89%
“…Stoichiometry between SPEC and NBD-Cl was checked using a continuous variation method (Job's method), [22] as described previously [20,23,24] by preparing 1 × 10 −4 M SPEC and NBD-Cl.…”
Section: Stoichiometry Mechanismmentioning
confidence: 99%
See 2 more Smart Citations
“…From the literature survey, different analytical methods have been reported for the analysis of DOR such as spectrophotometry, 2-5 spectrouorimetry, 6 high-performance liquid chromatography (HPLC), [7][8][9] high-performance thin layer chromatography (HPTLC) 10 and electrochemical 11 methods. From this survey, only one spectrouorimetric method was reported for the determination of DOR.…”
Section: Introductionmentioning