1967
DOI: 10.1063/1.1840908
|View full text |Cite
|
Sign up to set email alerts
|

Infrared Spectrum of Europium Acetylacetonate

Abstract: The infrared spectrum of europium acetylacetonate has been observed from 4000 to 200 cm−1 and a normal-coordinate calculation for the in-plane vibrations of the 1:1 single ring complex has been carried out. The Eu–O stretching frequencies are found to be in the region from 400 to 200 cm−1 and the Eu–O stretching force constant is estimated to be about 1.43×105 dyn/cm. The interpretation of the spectrum is discussed generally.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

1969
1969
2021
2021

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 22 publications
(3 citation statements)
references
References 12 publications
0
3
0
Order By: Relevance
“…According to the literature, a few absorption bands which are characteristic of Eu(acac) 3 are seen at around 1600-1200 cm −1 . 24 More specifically, three bands with very strong absorption are known to appear at 1600 cm −1 , 1515 cm −1 and 1450 cm −1 that can be attributed to CvC stretching, CvO stretching and the combination of C-H bending and CvO stretching, respectively. Another strong absorption should appear at around 1258 cm −1 , being ascribed to the combination of C-CH 3 stretching and CvC stretching.…”
Section: Resultsmentioning
confidence: 99%
“…According to the literature, a few absorption bands which are characteristic of Eu(acac) 3 are seen at around 1600-1200 cm −1 . 24 More specifically, three bands with very strong absorption are known to appear at 1600 cm −1 , 1515 cm −1 and 1450 cm −1 that can be attributed to CvC stretching, CvO stretching and the combination of C-H bending and CvO stretching, respectively. Another strong absorption should appear at around 1258 cm −1 , being ascribed to the combination of C-CH 3 stretching and CvC stretching.…”
Section: Resultsmentioning
confidence: 99%
“…In addition, the shape of the absorption band due to the OH group is changed because the ODA is removed by the solvent extraction process and the state of the adsorbed water is changed. Importantly, Eu­(acac) 3 is still present after the solvent extraction as we see some characteristic absorptions in the spectra for Solv- 0.5 -Eu/Ti and Solv- 2.0 -Eu/Ti . Although some amount of the adsorbed Eu­(acac) 3 is removed together with ODA by the extraction, there is no change in the PL intensity area between 604 and 640 nm per 1 mol of the Eu­(acac) 3 .…”
Section: Resultsmentioning
confidence: 80%
“…Importantly, Eu(acac) 3 is still present after the solvent extraction as we see some characteristic absorptions in the spectra for Solv-0.5-Eu/ Ti and Solv-2.0-Eu/Ti. 48 Although some amount of the adsorbed Eu(acac) 3 is removed together with ODA by the extraction, there is no change in the PL intensity area between 604 and 640 nm per 1 mol of the Eu(acac) 3 . Furthermore, internal quantum yields are almost equivalent between the samples before and after removing ODA (data not shown), indicating that the solvent extraction does not affect the fluorescent property but simply works to remove biotoxic ODA molecules.…”
Section: ■ Experimental Sectionmentioning
confidence: 99%