2022
DOI: 10.3390/en15124216
|View full text |Cite
|
Sign up to set email alerts
|

Influence of the Cable Accessories Installing Method on the Partial Discharge Activity in Medium Voltage Cables

Abstract: This article proposes a method to modify the construction of a medium voltage (MV) heat shrinkable cable termination in cases of atypical damage to the shields of cross-linked polyethylene (XLPE) insulated cables. The proposed solutions include a modified method of assembling electric field control coating. An attempt was made to check the effect of such damage to the shields of MV cables with XLPE insulation on the level of occurrence of partial discharges within the cable termination. The investigations incl… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 35 publications
0
2
0
Order By: Relevance
“…Another phenomenon related to the insulation degradation in PEC systems is the partial discharge phenomenon, which in various studies have been documented to cause long term degradation of dielectric material insulation properties [94]- [96]. Particularly in WBG enabled MV PECs the partial discharge inception voltage will decrease with higher dv/dt posing an increased threat in terms of reliability [97]- [101]. Another failure mechanism related to the parasitic capacitive couplings is the cross-talk induced MOSFET self turn on, which poses the risk of a phase-leg short circuit [102]- [105].…”
Section: Reliability and Thermal Stressesmentioning
confidence: 99%
“…Another phenomenon related to the insulation degradation in PEC systems is the partial discharge phenomenon, which in various studies have been documented to cause long term degradation of dielectric material insulation properties [94]- [96]. Particularly in WBG enabled MV PECs the partial discharge inception voltage will decrease with higher dv/dt posing an increased threat in terms of reliability [97]- [101]. Another failure mechanism related to the parasitic capacitive couplings is the cross-talk induced MOSFET self turn on, which poses the risk of a phase-leg short circuit [102]- [105].…”
Section: Reliability and Thermal Stressesmentioning
confidence: 99%
“…Transformers and gas-insulated switchgear are among the most studied equipment in this field of application [70]. Power lines, which include medium and high-voltage cables and related accessories, are also critical components in terms of PD [71]. From a practical point of view, offline PD testing can easily be performed using ultra high frequency (UHF) sensors, while online monitoring is developing with many research applications [72].…”
Section: Partial Discharge Measurementsmentioning
confidence: 99%