1989
DOI: 10.1016/s0003-2670(00)80315-3
|View full text |Cite
|
Sign up to set email alerts
|

Inductively coupled plasma-atomic emission spectroscopy. An atlas of spectral information

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
45
0
5

Year Published

1994
1994
2019
2019

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 53 publications
(61 citation statements)
references
References 0 publications
4
45
0
5
Order By: Relevance
“…A literature review reveals that different authors use the term 'fractionation' to describe related but subtly different phenomena [50][51][52][53][54] . In this dissertation, fractionation is a broad term for the processes by which elemental ratios of a solid sample are determined inaccurately by LA-ICP-MS.…”
Section: Fractionationmentioning
confidence: 99%
See 2 more Smart Citations
“…A literature review reveals that different authors use the term 'fractionation' to describe related but subtly different phenomena [50][51][52][53][54] . In this dissertation, fractionation is a broad term for the processes by which elemental ratios of a solid sample are determined inaccurately by LA-ICP-MS.…”
Section: Fractionationmentioning
confidence: 99%
“…The ablation process itself is also a source of fractionation; that is, the aerosol generated by laser ablation can have different composition than the actual solid sample 53,61 .…”
Section: Fractionationmentioning
confidence: 99%
See 1 more Smart Citation
“…However, because ICP-MS may be more affected by sample matrix effects such as 155 those typically encountered with surface wipes, this technique may not be as good a choice for analysis of surface wipes as ICP-AES. On the other hand, ICP-AES is subject to spectral interferences with all three of the primary lines used for beryllium (see Table 2) 32,33 Once samples are collected on air filters or surface wipes, the 175 beryllium is brought into solution, by digestion or extraction, prior to instrumental analysis. The ICP-AES, ICP-MS, and AAS methods rely on sample preaparation by an acid digestion involving one or more acids in combination with heat.…”
Section: History Of Beryllium Occupational Exposure Limitsmentioning
confidence: 99%
“…Most of the matrix effects are caused by the easily ionizable elements (EIEs) 22,23 . Anyway, several spectral interferences have been found in the determination of As and Pb by ICP-OES 24 . Direct spectral overlap interference due to Fe was found when Pb was determined in the emission 70 lines 217.000 nm and 283.306 nm 24,25 .…”
Section: Introductionmentioning