2017 American Control Conference (ACC) 2017
DOI: 10.23919/acc.2017.7963591
|View full text |Cite
|
Sign up to set email alerts
|

Induced vibration contact detection for minimizing cantilever tip-sample interaction forces in jumping mode atomic force microscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 16 publications
0
4
0
Order By: Relevance
“…A summary table of selected primary AFM modes of operation is provided in Table 2 . It is worth to notice that researchers have also developed other operation modes for specialized application such as the pulsed-force mode [ 17 ], induced-vibration contact detection mode [ 18 ], etc. For biomedical applications, the mechanical property and spectroscopy modes are more widely used and will be discussed in more details later in this review.…”
Section: Afm Basic Principlesmentioning
confidence: 99%
“…A summary table of selected primary AFM modes of operation is provided in Table 2 . It is worth to notice that researchers have also developed other operation modes for specialized application such as the pulsed-force mode [ 17 ], induced-vibration contact detection mode [ 18 ], etc. For biomedical applications, the mechanical property and spectroscopy modes are more widely used and will be discussed in more details later in this review.…”
Section: Afm Basic Principlesmentioning
confidence: 99%
“…To improve the demodulation speed, integration over integer number of periods is preferred over long time integration with low pass filter. Based on previous research, the oscillation amplitude can be extracted with only a few periods of the sinusoidal waveform [10]. With proper implementation of a pipeline for integration, the digital lock-in amplifier can produce amplitude value at the same throughput rate as that of the data acquisition.…”
Section: Afm Imaging System Designmentioning
confidence: 99%
“…A versatile imaging system is needed for various scenarios. Previous research efforts have focused on improving imaging speed of conventional AFM system by designing new generation scanners [8], utilizing smaller size cantilever probes with higher resonance frequencies [2], investigating new imaging modes [9,10], etc. As the imaging system throughput is proportional to the product of size, resolution and speed, simultaneously achieving high performances in all aspects is ideal but challenging [11].…”
Section: Introductionmentioning
confidence: 99%
“…Proportional-integral-derivative (PID) controllers are widely accepted by users due to their simplicity. Several earlier works in the field have attempted to implement multiactuated scanner designs and the associated control strategies such as data-driven PID approach foo multiactuated scanner 21,22 and induced vibration contact detection jumping mode operation 23 for high-speed and large range performance. However, due to the controller and operation complexity, the previously proposed solutions have not successfully found their way to the microscopy industry and into the hands of scientists using these microscopes.…”
Section: Introductionmentioning
confidence: 99%