2011
DOI: 10.1373/clinchem.2010.157115
|View full text |Cite
|
Sign up to set email alerts
|

Increasing Liquid Chromatography–Tandem Mass Spectrometry Throughput by Mass Tagging: A Sample-Multiplexed High-Throughput Assay for 25-Hydroxyvitamin D2 and D3

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
25
0

Year Published

2012
2012
2020
2020

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 55 publications
(25 citation statements)
references
References 21 publications
0
25
0
Order By: Relevance
“…In order to achieve such multiplexing of samples, each sample needs to become chemically modified in a different way, allowing unique identification by the MS instrument. Using this approach, a five-fold increased sample throughput has been achieved in the measurement of 25(OH)D in human serum [81]. When combining some of the above mentioned approaches, sample throughput can be increased even further.…”
Section: Sample Throughputmentioning
confidence: 99%
“…In order to achieve such multiplexing of samples, each sample needs to become chemically modified in a different way, allowing unique identification by the MS instrument. Using this approach, a five-fold increased sample throughput has been achieved in the measurement of 25(OH)D in human serum [81]. When combining some of the above mentioned approaches, sample throughput can be increased even further.…”
Section: Sample Throughputmentioning
confidence: 99%
“…However, it is still difficult to quantify the low endogenous levels of 1,25(OH) 2 VitD in small sample volumes. In an attempt to further increase the method sensitivity, new effective dienophiles, 4-(4′-dimethylaminophenyl)-1,2,4-triazoline-3,5-dione; 4-[2-(3,4-dihydro-6,7-dimethoxy-4-methyl-3-oxo-2-quinoxalinyl)ethyl]-3H-1,2,4-triazole-3,5(4H)-dione; and other "triazolinediones," have been developed (25,(33)(34)(35)(36)(37). Among them, the positively charged derivatization reagent, Amplifex-Diene and SecoSET, are reported to have a 10-fold ioniziation efficiency improvement over PTAD (25,36,38).…”
mentioning
confidence: 99%
“…However, the immunoextraction method was developed only for 1,25(OH) 2 VitD and did not include other metabolites, 25(OH)VitD and 24R,25(OH) 2 VitD. These metabolites are also important to quantify, because the 24R,25(OH) 2 VitD has proved to be a critical component for healing processes in tissues and bones, and knowing the levels of both 25(OH)VitD and 24R,25(OH) 2 VitD is useful for epidemiological studies (35). In addition, immunoextraction required a relatively large sample volume (400-500 µl) compared with other methods.…”
mentioning
confidence: 99%
“…In 2011, a group at Mayo Clinic developed and implemented an elegant mul tiplexing method where up to 5 patient samples are multiplexed within one single LC-MS/MS injection, using the specifically designed mass tags. The throug hput that can be achieved with this methodology is up to 300 specimens per hour or 7200 spe ci mens per instrument per day, matching the through put of automated immunoassays (37).…”
Section: Choice Of Methodsmentioning
confidence: 94%