2012
DOI: 10.2478/v10011-012-0022-1
|View full text |Cite
|
Sign up to set email alerts
|

Analytical methods and performance of the immunoassay methods for determination of vitamin d in comparison to mass spectrometry / Analitičke metode i izvođenje imunometrijskih određivanja vitamina d u poređenju sa masenom spektrometrijom

Abstract: Summary: Demand for vitamin D testing has been on a constant rise worldwide, partially due to mounting evidence linking vitamin D status to overall health and well-being. Currently available assays measure 25-hydroxy vitamin D (25-OHD), a major circulating form of vitamin D. Available methodologies include immunoassays and mass spectrometry based methods (LC-MS/MS). Until recently, the only immunoassays available for diagnostic use in the US have been DiaSorin radioimmunoassay (RIA) and an automated immunoassa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2016
2016
2020
2020

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 35 publications
0
3
0
Order By: Relevance
“…In addition, many laboratories rely on commercial immunoassay kits, which have their own pretreatment protocol that differs between laboratories. All of this causes sensitivity and specificity to fluctuate since many factors must be controlled (28,29). Otherwise, even when a good sample treatment is carried out, as well as an appropriate analytical method of vitamin D is chosen, vitamin D levels can be increased or decreased in the same person who maintains similar eating habits and of exposure to the sun during the year.…”
Section: Handling Of Vitamin D Samplesmentioning
confidence: 99%
See 2 more Smart Citations
“…In addition, many laboratories rely on commercial immunoassay kits, which have their own pretreatment protocol that differs between laboratories. All of this causes sensitivity and specificity to fluctuate since many factors must be controlled (28,29). Otherwise, even when a good sample treatment is carried out, as well as an appropriate analytical method of vitamin D is chosen, vitamin D levels can be increased or decreased in the same person who maintains similar eating habits and of exposure to the sun during the year.…”
Section: Handling Of Vitamin D Samplesmentioning
confidence: 99%
“…The quantification of vitamin D found in biological samples presents recognized difficulties (5). This circumstance coincides with an increase in studies to evaluate the content of vitamin D (6,7) occurring over the last decade, which has been attributed to two factors: on the one hand, the prevalence of serious deficiencies of this vitamin in poor countries and, on the other, an increase in the use of vitamin D as a general marker of health status and because of its relationship with various pathologies (8) Therefore, the need for quality research is paramount due to the aforementioned aspects, which cannot be avoided (23). The problem with immunoassays in the preparation of samples is that an antibody that is so specific to such a small antigen must be determined very clearly, in addition to the hydrophobicity of the vitamin and its binding protein (DBP), which would make oscillations in the amount of DBP present in the sample affect the immunoassay.…”
Section: Introductionmentioning
confidence: 96%
See 1 more Smart Citation