2017
DOI: 10.3928/1081597x-20170814-01
|View full text |Cite
|
Sign up to set email alerts
|

In Vivo Measurement of Longitudinal Chromatic Aberration in Patients Implanted With Trifocal Diffractive Intraocular Lenses

Abstract: Objective LCA was lower than subjective LCA, which was in agreement with previous studies on patients with phakic and monofocal IOLs. In vivo measurements of LCA enable understanding of the relative contribution of refractive and diffractive LCA and will eventually optimize IOL designs to improve polychromatic image quality. [J Refract Surg. 2017;33(11):736-742.].

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
23
0
2

Year Published

2017
2017
2021
2021

Publication Types

Select...
8

Relationship

7
1

Authors

Journals

citations
Cited by 20 publications
(28 citation statements)
references
References 31 publications
0
23
0
2
Order By: Relevance
“…The chromatic characterization of IOLs on optical bench, using in-vitro techniques and model eyes [7,10,11] to evaluate a variety of physical metrics based on the energy efficiency and modulation transfer function (MTF), does not provide an immediate and comprehensive understanding of its impact on vision. Some researchers have developed optical setups based on either wavefront sensing, laser ray tracing, double-pass retinal images, and psychophysical techniques to precisely and effectively measure LCA in vivo of pseudophakic patients [12] even at various focus distances [13]. Such optical setups frequently involve the use of sophisticated equipment with strict alignment requirements, the assistance of highly specialized personnel, and the recruitment of collaborative patients for time-consuming trials.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The chromatic characterization of IOLs on optical bench, using in-vitro techniques and model eyes [7,10,11] to evaluate a variety of physical metrics based on the energy efficiency and modulation transfer function (MTF), does not provide an immediate and comprehensive understanding of its impact on vision. Some researchers have developed optical setups based on either wavefront sensing, laser ray tracing, double-pass retinal images, and psychophysical techniques to precisely and effectively measure LCA in vivo of pseudophakic patients [12] even at various focus distances [13]. Such optical setups frequently involve the use of sophisticated equipment with strict alignment requirements, the assistance of highly specialized personnel, and the recruitment of collaborative patients for time-consuming trials.…”
Section: Introductionmentioning
confidence: 99%
“…To be suitable for the clinical practice, the apparatus and the examination procedure should be based on an effective in vivo measurement technique. Currently, these techniques apply either subjective psychophysical or objective reflectometric methods [13]. In case of considering a subjective psychophysical method, some properties are particularly valuable:…”
Section: Introductionmentioning
confidence: 99%
“…It was verified that the use of polychromatic TF VS ratio did not alter the evaluation of the theoretical SimVis temporal profiles in all M-IOL designs that do not involve longitudinal chromatic aberration (LCA) modulation [15]. However, the use of polychromatic SimVis temporal profile can improve [15], to a small extent, the replication of the TF VS ratio of the M-IOL that has the ability to correct the LCA [20] at specific distances.…”
Section: Discussionmentioning
confidence: 90%
“…As found in phakic eyes the LCA reflectometric methods (wavefront sensing and retinal imaging) underestimated the LCA obtained from psychophysical measurements. In a subsequent study the psychophysical LCA was measured in patients implanted with trifocal diffractive lOLs with the same hydrophilic and hydrophobic designs. Measurements were performed at far, intermediate and near distances.…”
Section: Vision Applications Of Viobio Adaptive Optics Lab Technologiesmentioning
confidence: 99%