2019
DOI: 10.15587/1729-4061.2019.185391
|View full text |Cite
|
Sign up to set email alerts
|

Improvement of the current control loop of the single-phase multifunctional grid-tied inverter of photovoltaic system

Abstract: source inverter (VSI) that combines the functions of an active power filter (APF) [2]. This contributes to increasing the utilization factor of CU due to its round-the-clock use [2-5] to maintain the maximum (close to one) power factor at the PCC to DG. The result is reduced load and energy loss in the DG. It is also possible to provide an autonomous mode of operation during the daytime [2, 3], stabilization of the load voltage [4]. Thus, improving the indicators of CU for systems with RES is an urgent task an… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
3
1

Relationship

3
1

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 15 publications
0
5
0
Order By: Relevance
“…1, 2. The model is built according to known principles using a unit to calculate the loss of power in the keys [23] by the instantaneous current and voltage values in accordance with the parameters of the transistors. The model parameters are: U g =220 V, network resistance Х g =0.04 Ohm, the inverter output filter R f =0.3 Ohm, C f =60 μF, reactor's L=0.00105 H and R=0.1 Ohm.…”
Section: Matlab Simulation Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…1, 2. The model is built according to known principles using a unit to calculate the loss of power in the keys [23] by the instantaneous current and voltage values in accordance with the parameters of the transistors. The model parameters are: U g =220 V, network resistance Х g =0.04 Ohm, the inverter output filter R f =0.3 Ohm, C f =60 μF, reactor's L=0.00105 H and R=0.1 Ohm.…”
Section: Matlab Simulation Resultsmentioning
confidence: 99%
“…It includes an internal circuit of current control (CCL) of the inverter and three proportional-integral (PI) voltage controllers VC, VC2, VC3 to stabilize the voltage at the inverter input U d at the predefined level 1 d U [22,23]. CCL can be implemented using a relay current controller [22,23], or width-pulse modulation (PWM). Below we consider an option with PWM.…”
Section: The Structure Of a Photovoltaic System Control Systemmentioning
confidence: 99%
“…With a power consumption of LO in excess of 10 kW, it is advisable to use three-phase multifunctional inverters while maintaining a power factor close to 1 at the point of common coupling (PCC) to the grid [5][6][7][8][9][10][11][12]. This allows to unload the grid from reactive power and ensures the symmetry of loading the phases of the grid at an unbalanced load [9][10][11][12].…”
Section: Literature Review and Problem Statementmentioning
confidence: 99%
“…Great attention has been paid to the increase in the quality of electrical energy when a multifunctional grid inverter is used. The technical solution of a single-phase inverter was presented in [8]. An improvement of the inverter characteristics, with fuzzy logic used, was then described in [9].…”
Section: Literature Review and Problem Statementmentioning
confidence: 99%
“…The purpose of the restriction is to reduce the number of deep discharge cycles of SB. Here, ∆Q* 24 is determined by (8).…”
Section: Implementation Variant For One-tariff Planmentioning
confidence: 99%