2017
DOI: 10.1016/j.egypro.2017.04.064
|View full text |Cite
|
Sign up to set email alerts
|

Improvement of District Heating Network Energy Efficiency by Pipe Insulation Renovation with PUR Foam Shells

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
7
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(7 citation statements)
references
References 9 publications
0
7
0
Order By: Relevance
“…The another important factor is heat loses occurred during heat transfer. This can be minimised by using proper insulation on the pipes [63]. The insulation which can be used is presented in Table 2.…”
Section: Heat Transfer Systemmentioning
confidence: 99%
“…The another important factor is heat loses occurred during heat transfer. This can be minimised by using proper insulation on the pipes [63]. The insulation which can be used is presented in Table 2.…”
Section: Heat Transfer Systemmentioning
confidence: 99%
“…To determine the geometric deviations, a set for visual and measuring control was used [22,30], which included a steel ruler, caliper with a depth gauge, a testing square, etc.…”
Section: Introductionmentioning
confidence: 99%
“…Analysis and generalization as the research methods were applied.At the second stage, by the method of visual and instrumental control, the study of pipes in polyurethane foam PE insulation at the manufacturing plant and at the construction site during installation was carried out. By the method of systematization, their main defects and damages revealed in the process of manufacturing and installation were classified.At the third stage, using the obtained quantitative data on the defects types and the reasons for their occurrence, the authors systematized the quality control requirements for the manufacturing process and installation of pipes in polyurethane foam PE insulation.To determine the geometric deviations, a set for visual and measuring control was used[22,30], which included a steel ruler, caliper with a depth gauge, a testing square, etc.…”
mentioning
confidence: 99%
“…Due to steady increase in energy prices, the prevailing share of non-renewable energy sources on total energy demand and limited energy resources, energy efficiency is becoming a topic of increasing importance. Among various energy saving measures, thermal insulation is known as one of the most cost-effective ways to improve energy efficiency [3] -as long as suitable insulation materials are used and a balance point between the cost and the energy savings is obtained [4].…”
Section: Introductionmentioning
confidence: 99%
“…Various studies have been carried out in order to define the optimum thermal insulation thickness of pipes. Zhang, L. et al [4] thermo-economically analyzed the optimum insulation thickness for buried pipes of district heating systems and investigated the impacts of various pipe diameters, fuel types and soil depths on energy savings and payback periods.…”
Section: Introductionmentioning
confidence: 99%