2014
DOI: 10.1109/mie.2014.2312427
|View full text |Cite
|
Sign up to set email alerts
|

Improved Reliability of Power Modules: A Review of Online Junction Temperature Measurement Methods

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
62
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
5
4
1

Relationship

2
8

Authors

Journals

citations
Cited by 178 publications
(63 citation statements)
references
References 49 publications
1
62
0
Order By: Relevance
“…Despite the efforts of the scientific community and power module manufacturers, the measurement of the junction temperature of power semiconductor devices is still a challenge. Over the years the problem has become more important due to the further increased power density of the new devices such as Silicon Carbide (SiC) power MOSFETs [1], [2] and [3].…”
Section: Introductionmentioning
confidence: 99%
“…Despite the efforts of the scientific community and power module manufacturers, the measurement of the junction temperature of power semiconductor devices is still a challenge. Over the years the problem has become more important due to the further increased power density of the new devices such as Silicon Carbide (SiC) power MOSFETs [1], [2] and [3].…”
Section: Introductionmentioning
confidence: 99%
“…Despite the high importance of the junction temperature, there is still no suitable low cost method for accessing the junction temperature of the power semiconductors: Direct measurement is only practical in laboratory environments, Thermo Sensitive Electrical Parameters (TSEP) affect additional components and sensor costs and observers or estimators deal with parameter uncertainties and high complexity for high precision [35]. Particularly, in modular power converters, there is the additional challenge of a high number of power semiconductors, resulting in many junction temperatures to be taken into account.…”
Section: A Thermal Principles and Lifetime Expectationmentioning
confidence: 99%
“…Because of a spatial distribution and power module packaging constraints, a direct measurement of temperature is not practical [10]. Hence, several methods are proposed using dynamic and static characteristics of power modules [11]. However, until today, few methods are discussing to make them applicable directly into a converter operation without any modification in a converter structure and control [12], [3].…”
Section: Temperature and A Power Limit Detectionmentioning
confidence: 99%