2000
DOI: 10.1016/s0002-9149(00)00734-7
|View full text |Cite
|
Sign up to set email alerts
|

Improved reliability for echocardiographic measurement of left ventricular volume using harmonic power imaging mode combined with contrast agent

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

4
13
0

Year Published

2001
2001
2010
2010

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 22 publications
(18 citation statements)
references
References 15 publications
4
13
0
Order By: Relevance
“…[11][12][13][14][15][16][17][18][19][20][21][22]25 Among these, the results of two 2D studies using the ultrasound contrast agent Levovist are in line with the present study (a significant increase in LV volumes), effects that were ascribed to ultrasound contrast filling up intertrabecular space. 17,19 A similar study with EchoGen showed a small but significant decrease in LV end-diastolic volume, and no change in LV endsystolic volume and ejection fraction measurements. 23 Conceivably, the difference in LV end-systolic volume measurements between the studies may represent relatively more destruction of ultrasound contrast agent in the intertrabecular zone in the EchoGen study.…”
Section: Discussionsupporting
confidence: 85%
See 3 more Smart Citations
“…[11][12][13][14][15][16][17][18][19][20][21][22]25 Among these, the results of two 2D studies using the ultrasound contrast agent Levovist are in line with the present study (a significant increase in LV volumes), effects that were ascribed to ultrasound contrast filling up intertrabecular space. 17,19 A similar study with EchoGen showed a small but significant decrease in LV end-diastolic volume, and no change in LV endsystolic volume and ejection fraction measurements. 23 Conceivably, the difference in LV end-systolic volume measurements between the studies may represent relatively more destruction of ultrasound contrast agent in the intertrabecular zone in the EchoGen study.…”
Section: Discussionsupporting
confidence: 85%
“…19,26 In one contrast echocardiography study, LV end-diastolic volume showed a larger increase than LV end-systolic volume, with a resulting increase in ejection fraction. 17 In this study, however, the amount of ultrasound contrast material that was injected was very small, which might have aggravated the effects of ultrasound contrast destruction.…”
Section: Discussionmentioning
confidence: 75%
See 2 more Smart Citations
“…The use of contrast echocardiography for opacification of the LV cavity enhances endocardial border delineation, thereby decreasing variability in the assessment of LV volumes and LVEF, and improving the interpretation of regional wall motion abnormalities 43 44 45 46 47. Malm et al evaluated the accuracy and reproducibility of contrast echocardiography versus tissue harmonic imaging for measurements of LV volumes and LVEF in 110 consecutive patients; MRI was used as an independent “gold standard” 43.…”
Section: Contrast Echocardiographymentioning
confidence: 99%