2016
DOI: 10.1109/tmag.2015.2500894
|View full text |Cite
|
Sign up to set email alerts
|

Impact of Slot/Pole Combination on Inter-Turn Short-Circuit Current in Fault-Tolerant Permanent Magnet Machines

Abstract: . (2015) Impact of slot/pole combination on inter-turn short-circuit current in faulttolerant permanent magnet machines. IEEE Transactions on Magnetics, 52 (4). ISSN 0018-9464Access from the University of Nottingham repository: http://eprints.nottingham.ac.uk/33837/1/Impact%20of%20Slot%20Pole%20Combination %20on%20Inter-Turn%20Short-Circuit%20Current%20in%20Fault-Tolerant%20Permanent %20Magnet%20Machines.pdf Copyright and reuse:The Nottingham ePrints service makes this work by researchers of the University of … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
14
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 35 publications
(14 citation statements)
references
References 20 publications
0
14
0
Order By: Relevance
“…A can be obtained from the formula (23), where x is the PM height, and a 1 = −0.07921, a 2 = 0.2211, and a 3 = 0.8577, when A is calculated for the Front side; but a 1 = −0.09392, a 2 = 0.01569, and a 3 = 0.9449, when A is calculated for the Flank side.…”
Section: (23)mentioning
confidence: 99%
See 1 more Smart Citation
“…A can be obtained from the formula (23), where x is the PM height, and a 1 = −0.07921, a 2 = 0.2211, and a 3 = 0.8577, when A is calculated for the Front side; but a 1 = −0.09392, a 2 = 0.01569, and a 3 = 0.9449, when A is calculated for the Flank side.…”
Section: (23)mentioning
confidence: 99%
“…Flux leakage was calculated by Li and Chau [15], where the possible flux paths of a PM linear vernier machine were analyzed and identified with an ideal flux source, making it suitable only for bar PMs. FEA has become the first choice of method for electromagnetic calculations on account of its great applicability and accuracy [16][17][18][19][20][21][22][23]; however, FEA cannot obtain the exact results with a low computational cost. The lumped parameter analytical method (LPAM) of an electromagnetic system depends solely on simple empirical formulae and these calculations are very imprecise.…”
Section: Introductionmentioning
confidence: 99%
“…Taking the current as fault signal, harmonic spectrum analysis is performed to determine whether the stator winding has an ISCF. In [8], the influence of different slot-pole match and the ISCF position of fault-tolerant PMSM on motor efficiency and short-circuit current are discussed. In [9], an adaptive fuzzy control system for PMBDCM is established.…”
Section: Introductionmentioning
confidence: 99%
“…The high turn fault current can also cause irreversible demagnetization of the magnets [5]. Significant effort has been devolved to fault tolerant machine design [6,7], fault modeling [8], fault detection and mitigation strategies [9] to avoid or at least alleviate the effects of this severe failure.…”
Section: Introductionmentioning
confidence: 99%