Hyphenation of capillary zone electrophoresis with mass spectrometry for proteomic analysis: Optimization and comparison of two coupling interfaces

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
17
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(17 citation statements)
references
References 35 publications
0
17
0
Order By: Relevance
“…To enrich weakly acidic and basic analytes, the difference in the pH between the sample matrix and BGE can be employed, which is known as the dynamic pH junction or the pH-mediated stacking. During the year 2019-2021, several reports on the pH-mediated stacking techniques have appeared for the CE analyses of p-cresols [62], peptides [63], kynurenine enantiomers [64], and sulfur-containing amino acids [65] as summarized in Table 5. Zhao et al reported a specific pH-mediated stacking technique with multisegmented injection to avoid ion suppression in CE-MS [66] for the determination of sulfur metabolites [65].…”
Section: Application Of Ph-mediated Stackingmentioning
confidence: 99%
“…To enrich weakly acidic and basic analytes, the difference in the pH between the sample matrix and BGE can be employed, which is known as the dynamic pH junction or the pH-mediated stacking. During the year 2019-2021, several reports on the pH-mediated stacking techniques have appeared for the CE analyses of p-cresols [62], peptides [63], kynurenine enantiomers [64], and sulfur-containing amino acids [65] as summarized in Table 5. Zhao et al reported a specific pH-mediated stacking technique with multisegmented injection to avoid ion suppression in CE-MS [66] for the determination of sulfur metabolites [65].…”
Section: Application Of Ph-mediated Stackingmentioning
confidence: 99%
“…However, despite the significant gain in sensitivity, the practical use is still impaired due to technical difficulties in assembling the interface, blocked emitter tips by particles and limited flushing routines of background electrolyte and sheath liquid. Also, manual replenishment of sheath liquid can be tedious and lead to uncontrolled electrolyte and sheath liquid compositions in the emitter tip by accident, as described in a recent publication [16]. These drawbacks prevent routine application of these nanointerfaces.…”
Section: Figurementioning
confidence: 99%
“…9−11 Other interfaces employ electrospray from the tip of the stainless steel or glass emitter. 7,12−14 The value of nanoflow SL interfaces to increase sensitivity in CE-MS has been proven several times recently, 7,10,15,16 and the commercialization of the interface developed by the Dovichi group as the EMASS-II interface (CMP Scientific) enabled access to this technique to a broader scientific community. 13 However, the setup and operation of these interfaces are laborious and need some experience and expertise.…”
Section: ■ Introductionmentioning
confidence: 99%
“…13 However, the setup and operation of these interfaces are laborious and need some experience and expertise. 16,17 Additionally, problems with bubble formation and emitter clogging hamper the analytical ruggedness.…”
Section: ■ Introductionmentioning
confidence: 99%