2015
DOI: 10.1016/j.chroma.2015.03.065
|View full text |Cite
|
Sign up to set email alerts
|

Hydrophilic-subtraction model for the characterization and comparison of hydrophilic interaction liquid chromatography columns

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
20
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 40 publications
(22 citation statements)
references
References 53 publications
2
20
0
Order By: Relevance
“…Currently, a common approach in targeted metabolomics is “RP for non-polar and HILIC for the rest”, which fails to take into account that HILIC columns are heterogeneous and their separation performance is less predictable than that of RP materials (6). The complex, multi-increment retention processes occurring in HILIC render this technique flexible but also more challenging in terms of method development and selectivity prediction (1820, 24, 25). .…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Currently, a common approach in targeted metabolomics is “RP for non-polar and HILIC for the rest”, which fails to take into account that HILIC columns are heterogeneous and their separation performance is less predictable than that of RP materials (6). The complex, multi-increment retention processes occurring in HILIC render this technique flexible but also more challenging in terms of method development and selectivity prediction (1820, 24, 25). .…”
Section: Resultsmentioning
confidence: 99%
“…LSER approaches utilize solute properties to establish system constants and characterize HILIC columns, for example by relating retention to hydrophobicity, charge state and H bond donor/acceptor properties (1820). However, such models have limited predictive power and are often impractical or inaccessible outside of dedicated chromatography research laboratories.…”
Section: Introductionmentioning
confidence: 99%
“…65 The hydrophilic-subtraction model is based on the major interactions governing HILIC retention, namely, hydrophilic partitioning, hydrogen-bonding and electrostatic interactions and is constructed using a format similar to the LSER model as shown in eqn (9): 65 The hydrophilic-subtraction model is based on the major interactions governing HILIC retention, namely, hydrophilic partitioning, hydrogen-bonding and electrostatic interactions and is constructed using a format similar to the LSER model as shown in eqn (9):…”
Section: Modelling Retention In Hilicmentioning
confidence: 99%
“…In eqn (9), all the capital letters are solute descriptors, H describing the hydrophilic partitioning ability of the solutes, A and B the solute hydrogen-bonding acidity and basicity, C and D the solution cation-exchange and anionexchange properties, respectively. 65 Although similar in format to the LSER model, it should be noted that the hydrophilic-interaction model is fundamentally different from LSER. Using 41 test solutes (including one reference solute, uracil) and 8 model columns (including one reference column, TSKgel-Amide 80), all the solute descriptors and system constants were calculated through multiple linear regression.…”
Section: Modelling Retention In Hilicmentioning
confidence: 99%
See 1 more Smart Citation