2013
DOI: 10.1109/tste.2013.2245689
|View full text |Cite
|
Sign up to set email alerts
|

Hybrid 2D-3D Space Vector Modulation Voltage Control Algorithm for Three Phase Inverters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
4
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 18 publications
0
4
0
Order By: Relevance
“…In this study, the concept of three-dimensional SVPWM [23] and control of the NPC [24] also used the idea of offset voltage in determining the modulation parameters [25]. The results of the analysis obtained have not yet reached the simulation and experimental stages.…”
Section: Modulation Parametersmentioning
confidence: 96%
“…In this study, the concept of three-dimensional SVPWM [23] and control of the NPC [24] also used the idea of offset voltage in determining the modulation parameters [25]. The results of the analysis obtained have not yet reached the simulation and experimental stages.…”
Section: Modulation Parametersmentioning
confidence: 96%
“…Once the tetrahedron containing the reference vector is defined, the switching vectors adjacent to v* are known. From the projections of the reference vector on the switching vectors that delimit the tetrahedron, the time that each switching vector must be applied was calculated in [21][22][23]. In this work, a symmetric distribution of the switching vectors has been implemented.…”
Section: Three-dimension Space Vector Modulatormentioning
confidence: 99%
“…In Table 2 the phase to neutral voltages of the different switching vectors are expressed taking into account that the low frequency components of the voltage between the middle point of the dc-link and the neutral of the mains are zero, so it can be considered that the neutral point of the grid and the middle point of the dc-link are virtually connected at the frequency of the fundamental line voltage [19]. The tetrahedron that contains the reference vector must be calculated to obtain the switching vectors that must be applied [20]. It is necessary to calculate the time of application of the vectors, projecting the reference vector to the switching vectors that delimit the tetrahedrons.…”
Section: Three-dimension Space Vector Modulatormentioning
confidence: 99%
“…Then, some results are presented to validate the concept. The tetrahedron that contains the reference vector must be calculated to obtain the switching vectors that must be applied [20]. It is necessary to calculate the time of application of the vectors, projecting the reference vector to the switching vectors that delimit the tetrahedrons.…”
Section: Application To a 2 Mw Pv System Composed By Four 500 Kw Modumentioning
confidence: 99%