2018
DOI: 10.1088/1742-6596/1107/3/032014
|View full text |Cite
|
Sign up to set email alerts
|

High-Throughput Fire Tests and Weathering-Induced Degradation Behaviour of Intumescent Coatings

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0
2

Year Published

2020
2020
2022
2022

Publication Types

Select...
3
1

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 6 publications
0
3
0
2
Order By: Relevance
“…Apart from the above, there are publications relating the data from different polymers with rapid mass calorimeter, cone calorimeter, and PCFC [ 11 , 12 ]. More importantly, from the context of this manuscript, there are also many publications on different fire-retardant polymer-based coatings on small steel panels [ 13 , 14 , 15 , 16 ], some [ 17 , 18 , 19 , 20 , 21 , 22 , 23 , 24 ] of which use a bulk-scale test setup to evaluate the performance of intumescent coatings. Bulk-scale test involves the use of a coated substrate and the amount of materials involved is typically measured in grams.…”
Section: Introductionmentioning
confidence: 99%
“…Apart from the above, there are publications relating the data from different polymers with rapid mass calorimeter, cone calorimeter, and PCFC [ 11 , 12 ]. More importantly, from the context of this manuscript, there are also many publications on different fire-retardant polymer-based coatings on small steel panels [ 13 , 14 , 15 , 16 ], some [ 17 , 18 , 19 , 20 , 21 , 22 , 23 , 24 ] of which use a bulk-scale test setup to evaluate the performance of intumescent coatings. Bulk-scale test involves the use of a coated substrate and the amount of materials involved is typically measured in grams.…”
Section: Introductionmentioning
confidence: 99%
“…An evaluation of the testing procedure and comparison with the standard test according to DIN 4102-8 39 was presented in our previous work. 26 The foaming of the sample during the fire test can be observed through a small window in the furnace (Figure 3(a) and (c)).…”
Section: Methodsmentioning
confidence: 99%
“…2,18,2325 Depending on the environmental conditions, APP may react with MEL, as we discovered in a previous work. 26 Both mechanisms can disrupt the optimum matching of the chemical components in the intumescent coating. 24…”
Section: Introductionmentioning
confidence: 99%
“…In der Fachliteratur wurden bereits Untersuchungen zum Alterungsverhalten von RBS vorgestellt [1][2][3][4][5][6]. Sowohl die thermische Schutzwirkung als auch die Expansion kann durch äußere Umwelteinflüsse abnehmen.…”
unclassified
“…Sowohl die thermische Schutzwirkung als auch die Expansion kann durch äußere Umwelteinflüsse abnehmen. Die Degradation wird wesentlich von der chemischen Zusammensetzung des RBS und der Wasserlöslichkeit der einzelnen Bestandteile beeinflusst [1][2][3][4]. Durch die Applikation eines Decklacks kann die Dauerhaftigkeit erheblich verbessert werden [6].…”
unclassified