2016
DOI: 10.1016/j.ymeth.2016.02.002
|View full text |Cite
|
Sign up to set email alerts
|

High-repetition rate laser ablation coupled to dielectric barrier discharge postionization for ambient mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
18
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 18 publications
(18 citation statements)
references
References 30 publications
0
18
0
Order By: Relevance
“…Interestingly, the observed ion pattern for this novel set-up resembles mainly the spectral pattern which was obtained previously with this set-up in combination with a heliumdriven dielectric barrier discharge ion source. 18 Likewise, protonated water clusters dominated the reagent ion mass spectrum. Moreover, unambiguous identification of active ammonia formation due to plasma interactions with ambient N 2 and H 2 O was described.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Interestingly, the observed ion pattern for this novel set-up resembles mainly the spectral pattern which was obtained previously with this set-up in combination with a heliumdriven dielectric barrier discharge ion source. 18 Likewise, protonated water clusters dominated the reagent ion mass spectrum. Moreover, unambiguous identification of active ammonia formation due to plasma interactions with ambient N 2 and H 2 O was described.…”
Section: Resultsmentioning
confidence: 99%
“…Ion transfer into the first pumping stage (~10 -1 mbar) was achieved fluiddynamically using a home-built skimmer inlet. 18 Briefly, it consists of a metal plate extended by a commercially available conical nozzle. The inner diameter is 150 µm at the inlet towards atmospheric pressure and increases linearly to 4 mm at the low pressure end.…”
Section: Instrumentationmentioning
confidence: 99%
See 1 more Smart Citation
“…LD‐DBDI experiments using an Nd:YVO 4 laser with wavelength of 532 nm, repetition rates of several kHz, and pulsed energies below 100 μJ (Fig. 21) were also performed for the detection of a variety of samples such as pure amino acid molecules and capsaicin in dried chili fruits (Bierstedt & Riedel, 2016). In a recent report, a CW diode laser tuned at 405 nm was coupled to an LTP probe for profiling of alkaloids from cactus sample, jimsonweed fruit and seed, and tobacco seeding with lateral resolutions from 300 to 50 μm (Moreno‐Pedraza et al, 2019).…”
Section: Laser Desorption/ablation Coupled To Ambient Ionization In Bioapplicationsmentioning
confidence: 99%
“…( c ) Photograph of the laser ablation process of a tablet followed by DBD postionization. Reprinted from Bierstedt and Riedel (2016). LD‐DBD, laser desorption dielectric barrier discharge.…”
Section: Laser Desorption/ablation Coupled To Ambient Ionization In Bioapplicationsmentioning
confidence: 99%