2010
DOI: 10.1016/j.jchromb.2010.10.024
|View full text |Cite
|
Sign up to set email alerts
|

High performance liquid chromatography assay with ultraviolet detection for moxifloxacin: Validation and application to a pharmacokinetic study in Chinese volunteers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
37
0
1

Year Published

2012
2012
2020
2020

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 40 publications
(38 citation statements)
references
References 22 publications
0
37
0
1
Order By: Relevance
“…Even though fluorogenic derivatization procedures require heat and longer time, in this study, no heating procedure or long reaction time is needed. Moreover, the RSD, RME, and recovery values indicate that the proposed method is more precise and accurate than some previously reported methods (4)(5)(6)(7)(8)(9). Most of the reported methods also depend on RP-HPLC techniques (3)(4)(5)(6)(7)(8), but differently, the presented method has the shortest retention time.…”
Section: Validation Of the Methodsmentioning
confidence: 62%
See 1 more Smart Citation
“…Even though fluorogenic derivatization procedures require heat and longer time, in this study, no heating procedure or long reaction time is needed. Moreover, the RSD, RME, and recovery values indicate that the proposed method is more precise and accurate than some previously reported methods (4)(5)(6)(7)(8)(9). Most of the reported methods also depend on RP-HPLC techniques (3)(4)(5)(6)(7)(8), but differently, the presented method has the shortest retention time.…”
Section: Validation Of the Methodsmentioning
confidence: 62%
“…In literature, it is revealed that MOX has been determined in biological fluids: high-performance liquid chromatography (HPLC) [3][4][5][6][7][8][9][10][11], voltammetry [12], and capillary electrophoresis with laser-induced fluorescence [13]. None of them is for breast milk analysis.…”
Section: Introductionmentioning
confidence: 99%
“…The bactericidal action of Moxi results from trapping of enzymes on DNA and lethal release of doublestranded breaks, thereby inhibiting of cell replication [3]. Various analytical methods have been cited in literature for Moxi determinations including spectrophotometry, spectrofluorimetry, atomic absorption spectrometry, conductometry, voltammetry [4][5][6][7][8][9][10], high performance liquid chromatography-ultraviolet (HPLC-UV), HPLC-fluorescence(HPLC-Fl), capillary electrophoresis(CE), and HPLC-mass spectrometry (HPLC-MS) [4][5][6][7][8][9][10][11][12][13][14][15][16][17].…”
Section: Introductionmentioning
confidence: 99%
“…However, most of these methods involve time-consuming sample preparation steps or not usual techniques, e.g., protein precipitation followed by an extra wash step with methylene chloride [6] or prior sample concentration [7], liquid-liquid extraction with 3 mL of ethyl acetate [8] or 5 mL of dichloromethane per sample [9], expensive solid-phase extraction device [5,10,11], and column switching [12]. Use of special additives in mobile phase composition, such as buffers associated to ion pair reagents [11,13], can eventually adsorb to the stationary phase and, thus, reduce column efficiency and lifetime.…”
Section: Introductionmentioning
confidence: 99%